background image

[6] 

 LOW IMPEDANCE 

This output allows the connection of low impedance standard speakers. The lowest load 
impedance must be 8 

. When two or more speakers are connected to this output they must 

be interconnected so that the load impedance is between 8

 and 16 

PREAMP/MIXER AND POWER AMP INTERCONNECTION 

The connection of the preamp/mixer to the FS-2481E power amp can be made with different 
connectors, depending on user preference: 

- Using balanced XLR connectors.
- Using balanced stereo 6.3 mm jack connectors.
- Using unbalanced RCA connectors.

POWER AMPLIFIER CONFIGURATION 

-

Internal selection of INPUT SENSITIVITY: 

The amplifier has three selectable input

sensitivities (1 V, 500 mV, 100 mV). Disconnect the amplifier from the mains, remove
the lid and select the input sensitivity in the SW401 selector on the PAB-1 printed
circuit board. The input sensitivity is 500 mV by default.

- Working mode selection: When several power amps are interconnected there is a

possibility to select the working mode in each one of them.
Working modes:

- One unit: For systems working as just one unit, select the STAND ALONE position in the

SW403 and SW404 selectors. This is the usual way of working and is the default
configuration. Several amps can be used in cascade, each one maintaining its own
volume.

- More than one unit: With two or three units working in cascade, one must be assigned

the role of MASTER. This is done by selecting this position in the SW403 and SW404
selectors. The others must be assigned the secondary role of SLAVE. In this working
mode the MASTER VR volume control is cancelled in the secondary units and the
volume is controlled by the MASTER unit.

The working modesare selected using 2 selectors (SW403 and SW404) found on the PAB-1 
printed circuit board. 

SW403 

SW404 

WORKING MODES 

STAND ALONE (default configuration, only one system) 
MASTER (Main unit) 
SLAVE (Secondary unit) 

The working mode is STAND ALONE by default. 

IMPORTANT:

 For the amps to work as MASTER and SLAVE, the input and output signal 

connection must be made exclusively using the UNBALANCED RCA connectors. 

Summary of Contents for FS-2481E

Page 1: ...MONO POWER AMPLIFIER INSTRUCTION MANUAL...

Page 2: ...ernal parts is dangerous and you could receive an electric shock The machine must not be splashed or dripped on Never place recipients with liquid inside on the machine Do not place anything inside th...

Page 3: ...even in normal working conditions The symbol formed by an exclamation mark in a triangle shows that the instruction manual must be referred to for information on how the machine works and its use The...

Page 4: ...on the machine EXEMPTION OF LIABILITY The characteristics of the equipment and the content of the manual can change without forewarning FONESTAR S A does not assume responsibilities regarding the inap...

Page 5: ...g the earth terminal The system is electrically more stable if the chassis is connected to earth NOTE The connection cable to the batteries must have a series rating fuse The fuse must be F30A quick c...

Page 6: ...onnected there is a possibility to select the working mode in each one of them Working modes One unit For systems working as just one unit select the STAND ALONE position in the SW403 and SW404 select...

Page 7: ...amps BLOCK DIAGRAM UNBALANCED RCA INPUT SECONDARY SLAVE POWER AMP FONESTAR model FS 2241E BALANCED INPUT BALANCED OUTPUT UNBALANCED INPUT UNBALANCED OUTPUT PRIORITY SWITCH Sensitivity selector VR MAST...

Page 8: ...ectives 2004 108 EC on Electromagnetic Compatibilty Santander 28th May 2009 Juan Vallejo Technical Engineer Sales Department WARRANTY This product has been tested and has passed the corresponding qual...

Page 9: ...ntact FONESTAR if it is impossible or imposes an undue burden for them to solve it To benefit from this warranty it is necessary to show the proof of purchase with the date clearly visible with no cor...

Reviews: