24 channels (P):
CHANNEL
VALUE
FUNCTION
CH1
000-255
leds 1 to 3
Red intensity
CH2
000-255
Green intensity
CH3
000-255
Blue intensity
CH4
000-255
leds 4 to 6
Red intensity
CH5
000-255
Green intensity
CH6
000-255
Blue intensity
CH7
000-255
leds 7 to 9
Red intensity
CH8
000-255
Green intensity
CH9
000-255
Blue intensity
CH10
000-255
leds 10 to 12
Red intensity
CH11
000-255
Green intensity
CH12
000-255
Blue intensity
CH13
000-255
leds 13 to 15
Red intensity
CH14
000-255
Green intensity
CH15
000-255
Blue intensity
CH16
000-255
leds 16 to 18
Red intensity
CH17
000-255
Green intensity
CH18
000-255
Blue intensity
CH19
000-255
leds 19 to 21
Red intensity
CH20
000-255
Green intensity
CH21
000-255
Blue intensity
CH22
000-255
leds 22 to 24
Red intensity
CH23
000-255
Green intensity
CH24
000-255
Blue intensity
- It is possible to cascade several devices to be managed together (if they are in the same DMX address)
or separately (if they are in different DMX addresses).
Use an XLR cable to connect the device's DMX IN to the DMX OUT of the DMX controller when the device
is the first element in the chain. Alternatively, connect to the DMX OUT of the preceding element in the
lighting chain of your installation.
You can also supply power from one light to the next in the chain in the same way as shown in the picture
(POWER IN - POWER OUT).
LED BAR 24 x 3 W
BAR-73L
POWER OUT
4 A MAX.
DMX OUT
DMX IN
GND
POWER IN
MODE
SET
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
LED BAR 24 x 3 W
BAR-73L
POWER OUT
4 A MAX.
DMX OUT
DMX IN
GND
POWER IN
MODE
SET
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DMX OUT
DMX IN
POWER IN
POWER IN
POWER OUT
POWER OUT
DMX IN
DMX OUT
DMX IN
DMX CONTROLLER
LED BAR 24 x 3 W
BAR-73L
POWER OUT
4 A MAX.
DMX OUT
DMX IN
GND
POWER IN
MODE
SET
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
To interconnect them, you must use XLR cables with the following configuration:
1
2
3
Masa
XLR macho (vista pines)
Señal +
Señal -
1
2
3
Massa
XLR macho (vista pinos)
Sinal +
Sinal -
1
2
3
Ground
Male XLR (pin view)
Signal -
1
2
3
Masse
XLR mâle (vue broches)
Signal -
ES
PT
EN
FR