8
DETAILS OF BATHROOM INSTALLATION
The appliance must be installed according to current regulations and laws in force in the country of use.
The radiator is class II and has IPX4 electrical protection. In bathrooms, it can be installed in areas 2 and 3 (see figure 1) on condition that the control
device is not within reach of people using the shower or bathtub.
The radiator must not be connected to the earth lead.
In the bathroom, protect the power line with a 30 mA high sensitivity differential device.
Install a multi-pole circuit breaker. The distance between the contacts must be at least 3 mm.
2,5 m
fig. 1
6. REGULATION AND PROGRAMMING
The control panel has two controls: the left-hand control is used to select
the operating mode, while the right-hand control is used to programme
the room temperature.
Operating mode control
Temperature control
LED
fig. 2
AREAS 0
AREAS 0
AREAS 1
AREAS 2
AREAS 3
There is also a LED light which turns green when the ambient temperature has reached the level programmed by the user and red when the
temperature in the room is lower than the level programmed and the heating element is receiving power.
There are five operating modes: Comfort, Night-time reduction, Anti-freeze, Off, Pilot wire.