USING THE WINEMASTER SP100
5.1
CONNECTING THE AIR-CONDITIONER
Connect the male plug to a 230/16A power socket. Switch on the air-conditioner by pressing the green button
on the back of the inside unit..
The fan on the cellar side comes on immediately.
The compressor may not come on until 2 minutes later if the temperature in the cellar is higher than the set
temperature. If the cellar temperature matches the thermostat setting, the compressor will not come on.
5.2 CONTROL
PANEL
The setting of the targeted temperature of the cellar is made on the thermostat .
Use the following process
:
Press the button
1
one seconde until the message
o1
appears. Press then
the button
3
, the set temperature of the cellar will appear. Use again the
button
1
to increase the temperature or the button
2
to lower the temperature.
When the right temperature is set, press the button
3
to confirm it.
AUTOMATIC DEFROST
The program of the thermostat from model WINEMASTER SP100 will run an automatic defrost time several
times a day. During this position, the compressor stops and only the fan in the cellar is functionning.
The condensate water produced during this period will b evacuated through the tube.
6
SERVICING THE WINEMASTER AIR-CONDITIONER
THE DUST FILTER
It is essential to replace the dust filter in the air-conditioner as soon as necessary and at least once a year. If it is
clogged, the air-conditioner could be seriously damaged.