background image

9

 

 

2. INSTRUCTION FOR THE INSTALLER 

 
CAUTION: the following procedure requires specific skills and adjustments while the flame is on 
may  cause  damage  to  persons  or  things  if  not  carried  out  with  due  skill  and  competence.  The 
modification  of  the  appliance  on  part  of  unauthorized  people,  will  invalidate  any  liability  of  the 
manufacturer in case of malfunction and/or damage caused by the malfunction of the cooker. 
 
The cooker comes with an LPG or methane gas predisposition (this is specified in the plate located 
under Elios). 
The appliance comes with the nozzle to be able to use the other gas. 
You may request the nozzles for other types of gas. 
 

2.1 LAWS, TECHNICAL REGULATIONS AND GUIDELINES 

 
- Comply with all applicable regulations in your country. 
- Standards for Accident Prevention 
- you must always apply a cut-off valve between the appliance and the gas line. 

 

2.2 FUME EXHAUST FOR "A" TYPE APPLIANCES 

 
Elios is an A1 type appliance so it needs to be placed in a well ventilated area to prevent the 
concentration of substances that are harmful to health. 
The area can be ventilated naturally by means of permanent openings on the walls, such as doors, 

windows (minimum opening of 100 cm

2

) or ventilation ducts (minimum opening of 150 cm

2

), or it 

can be forced by using electric fans (minimum capacity 15,48 m

3

/h). Make sure that ventilation is 

suitable and that it complies with all regulations in force. 
 

2.3 INSTALLATION OF ELIOS 

 
Use only the gas that is compatible with the cooker. 
Place Elios no less than 20 cm from the walls.

 

 

- check that the gas line solenoid valve is shut. 
- Connect the appliance to the gas system using rigid metal tubes or flexible stainless steel tubes in 
accordance with applicable regulations. 
If you use flexible tubes, check that they are not crushed or deformed. 
Connect the gas to the hose connection (

point 4 figure 2.A

) supplied by means of a tube clamp (or 

other  method  accepted  by  applicable  laws) 

checking  the  presence  of  the  seal  in  the  hose 

connection

- With a solution of soap and water, check that there are no leaks. If there are leaks, you will be able 
to see some bubbles. 
-  If  the  burner  is  powered  with  gas  bottle  and  it  has  a  variable  flow  regulator,  the  minimum 
regulation must be set following the procedure of paragraph 2.4 under point 15. 

 

CAUTION: never check for leaks with the use of fire! 

Summary of Contents for ELIOS PLUS

Page 1: ...ELIOS PLUS ELIOS WOK INSTRUCTIONS FOR USE AND INSTALLATION E N...

Page 2: ...V 01 18...

Page 3: ...domestic use with which they may come into contact Our appliances also comply with the Gas Directive 2009 142 EC INSTRUCTION BOOKLETS We hereby declare that all the captions in accordance with the na...

Page 4: ...ctly we recommend that you remove only the 4 hooks at the bottom between the wooden base and the box sides Table of contents 1 USER MANUAL 5 1 1 ADVICE AND WARNINGS 5 1 2 FIRST USE 7 1 3 USE 7 1 4 CLE...

Page 5: ...tilation for example open a window In case of malfunction please contact technical support The manufacturer cannot be held responsible for damaged caused by improper or incorrect use of the appliance...

Page 6: ...6 Figure 1 A 1 gas control knob 2 basin securing screws 3 burner 4 gas ring 5 basin 6 safety valve sensor 7 pilot 8 venturi 9 LPG or Methane hose nozzle with seal ring...

Page 7: ...tioning of the burner or of the gas ring may cause an uncontrolled release of gas thus a danger to persons and things 1 3 USE Closed faucet Pilot flame Maximum capacity Minimum capacity Figure 1 B Mak...

Page 8: ...os correctly use only mild soap or products that are suitable for enamel surfaces Do not use abrasive products Dry with a soft cloth Despite the anti acid treatment of the surfaces acidic products suc...

Page 9: ...can be ventilated naturally by means of permanent openings on the walls such as doors windows minimum opening of 100 cm 2 or ventilation ducts minimum opening of 150 cm 2 or it can be forced by using...

Page 10: ...remove it point 2 figure 1 A 4 Remove the hose connection point 4 figure 2 A remove the seal inside and place it inside the hose connection supplied in the bag the LPG one has a tight hole while the m...

Page 11: ...the air regulation ferrule figure 2 C using a small screwdriver until you get the desired flame CAUTION this procedure is dangerous Be very careful to turn the knob ONLY in pilot position 14 After tur...

Page 12: ...12 0 mm 3 0 mm 16 5 mm 4 0 mm GAS PILOT NOZZLE 0 21 0 40 0 21 0 40 GAS NOZZLE 145 220 145 220 Table 1 2 5 TECHNICAL CHARACTERISTICS Table 2 TOTAL GAS CONSUMPTION MODEL LPG METHANE ELIOS PLUS 9 0 3 0...