HD SERIES

Countermeasure on breakdown

9

Status

Expected cause

Point of checking and action

Slave is
impossible.

Slave button is turned OFF.

Check if slave button is turned ON.

Slave sensor is out of the light 
of flash.

After turning the lighting by 180° so as 
for turning sensor to be shown, and than 
operate it again.

Too strong light is on slave sensor.

Block direct ray of light or bright light 
from slave sensor.

Synchro Cord 
doesn’t 
become
tuned.

Due to dust or other material on 
synchro jack, it causes contact’s 
defective.

After checking synchro jack, remove 
other material.

Synchro cord has defective contacts
and is disconnected.

Replace synchro cord.
(Check if it can radiate by pressing 
ready button.)

There’s no 
reaction at all.

Power supply is blocked.

• Check if power cord is well connected.
• Check if the contact of socket is loose.
• Check if fuse is disconnected.

Others

Contact our company or its seller.

Summary of Contents for HD1000

Page 1: ...HD SERIES HD150 200 400 600 900 1000 1200 User Manual ...

Page 2: ...of fie if you use softbox made from combustible material so use softbox has over certain grade or is made out of incombustible material like glass fiber 7 Be careful against electric shock when using in a damp place 8 Keep out of children s reach Warning The lamp must be changed if it has become damaged or thermally deformed Shields lenses or screens must be changed if they have become visibly dam...

Page 3: ...HD SERIES Procedure 3 Before using Name of each part Name and function of control panel Operating way Specifications Method of managing and keeping Countermeasure on breakdown page 2 4 5 6 7 8 9 ...

Page 4: ...tion cap Modeling Halogen lamp Flash tube Xenon tube Accessory disassembling and assembling locking knob Slave sensor Lighting knob Stand stud joint fastening bolt Stand stud joint part Prop fastening bolt Knob for fastening Control panel ...

Page 5: ...ghtness of modeling halogen lamp Synchro X It s a terminal that connects synchro cord Slave sensor It has function to slave the light of other lighting Slave ON OFF button It s a function to select whether to slave with other lighting ON Slave OFF Unslave Overheat signaling lamp It turns on when inside circuit of lighting is overheated and on this case turn off the power and cool the lighting befo...

Page 6: ... lamp with modeling lamp control volume 7 Control the power with power control volume 8 If you want to tune this with other lighting turn on the slave button 9 If you change the power from high to low ready lamp might flicker If so discharge by pressing ready button before using 10 Sound lamp turns on when you press the sound button Sound is generated according to the change of power If power is c...

Page 7: ... F8 F64 6f stops F82 F642 6f stops Color Temperature 5500 K 150 K Ready Charge LED Light Buzzer ALARM ON Modeling Lamp Blinking ALARM OFF Modeling Lamp GX6 35 Base Modeling Control Analog Dial Volume Triggering Methode Synchro Sensor Ready Button Svnchro Cord Triggering Voltage DC 8V Over Temp Warning O T Red LED Blinking Buzzer Warning Sound Size W L H mm 235 140 170 280 140 170 350 140 170 Weigh...

Page 8: ...e Separate the power cord from the AC socket Eject the fuse holder using a straight screwdriver Remove the existing fuse and install the spare fuse which is also inside the fuse holder Be sure not to let dust stain the discharge tube and modeling lamp with replacing the fuse If dust or other materials get stuck to the discharge tube or lamp it can shorten the life of the lamp and deteriorate the c...

Page 9: ...r Block direct ray of light or bright light from slave sensor Synchro Cord doesn t become tuned Due to dust or other material on synchro jack it causes contact s defective After checking synchro jack remove other material Synchro cord has defective contacts and is disconnected Replace synchro cord Check if it can radiate by pressing ready button There s no reaction at all Power supply is blocked C...

Page 10: ...HD SERIES MEMO 10 ...

Page 11: ...HD SERIES MEMO 11 ...

Page 12: ......

Reviews: