Specifi cations
Electrical
1.
Models with Satellite-fi ll icemakers (110CR400A/W)
Icemaker
Max. fuse
Dispenser
Max. fuse
Basic electrical: 115V/60Hz/1 phase
11.0 amps
20 amps
4.0 amps
20 amps
2.
Freestanding models and models with integral icemakers (110FB400A/W, 110CT400A/W)
Total system Max. fuse
Basic electrical: 115V/60Hz/1 phase
14.0 amps
20 amps
3.
Dispensers and Satellite-fi ll icemakers are supplied with 7-foot power cord with NEMA 5-20 hospital grade plug.
Connect to 20 amp circuit fuse or breaker.
Note:
It is preferred that circuit be protected by a GFCI.
Ambient
Air temp
100 F/38 C max.
50 F/10 C min. (best performance below 80 F/27 C)
Water temp
90 F/32 C max.
40 F/4 C min. (best performance below 70 F/21 C)
Water pressure
70 P.S.I. max.
10 P.S.I. min.
Plumbing
110CR with
110CT with
110FB with
Satellite-fi ll icemaker
integral icemaker
icemaker in base
Dispenser drain
3/4" FPT
3/4" FPT
3/4" FPT
Icemaker drain
3/4" MPT
3/4" MPT
3/4" MPT
Dispenser water inlet
3/8" FPT
3/8" FPT
3/8" FPT
Icemaker water inlet
–
3/8" FPT
–
Satellite-fi ll IM water inlet
3/8" OD push-in
–
–
Cond. inlet – w/c only
3/8" FPT
3/8" FPT
3/8" FPT
Cond. drain – w/c only
3/8" FPT
3/8" FPT
1/2" FPT
Note:
Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard piped and insulated, and maintain
slope of at least 1/4" per foot (6mm per 305mm run) of slope. All plumbing connections must be made in accordance with
local building codes.
Ventilation clearances
Countertop models with Satellite-fi ll icemaker (110CR400A/W) — none. 12" (775mm) at top advised for service.
Countertop models with integral icemaker (110CT400A/W) — 6" (153mm) at top. 6" (153mm) each side advised for
service.
Freestanding models (110FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top advised for service.
5