HARMONY • TOP-MOUNT
self-contained
5
Prepare the installation site.
2
1/4"
1'
5-15
NEMA
H_C700A/W
H_D700A/W
6-15
NEMA
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of
icemaker in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
Electrical
➊
• H_C700(A/W)HT 208-230/60/1-15 amp breaker • H_D700(A/W)HT 115/60/1-15 amp breaker
(H_C700A/W Requires a 15 amp dedicated circuit)
(H_D700A/W Requires a 15 amp dedicated circuit)
• H_E700(A/W)HT 230/50/1-15 amp
‡
breaker
(H_E700A/W Requires 15 amp circuit 1.50 mm
2
wire)
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
➋
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Water supply must be treated by a scale-inhibiting fi lter (item# 00130286)
Condenser water supply for water-cooled systems
➌
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 20 to 90 F (-7 to 32C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
➍
• The drain line from the ice machine must be vented and have at least 1/4” per foot
(6,4mm/0,3m) pitch
115V ±5%
208V -5% to 230V +5%
Installation site requirements
2.1