26
HCE1010A/W, HME1010A/W, HCE1410A/W, HME1410A/W
Reservoir/rear bushing disassembly
Fig. 33
1. Press CLEAN button to purge
evaporator. Turn power OFF
when LO WATER lights.
Note: In many applications,
removing the gearmotor,
main housing, and
auger will allow for
the ice machine to be
pulled out further for
better access to rear
components.
2. Slide ice machine forward to
gain access.
3. Use Fig. 32 as disassembly
guide.
Note: Use petrogel when
installing/reinstalling
o-rings.
Refrigeration system
1010 - Refrigerant pressure data
Air-cooled condensers (air)
60 F/16 C
70 F/21 C
80 F/27 C
90 F/32 C
100 F/38 C
Pressure (psig) discharge/suction
190/32
225/34
258/36
292/39
325/41
System Operating Pressures (Discharge/Suction) PSIG
Potable Water F/C
Condenser W
at
er
F/C
50/10
60/16
70/21
80/27
90/32
50/10 260/34 260/34 260/34 260/34
260/34
psig
60/16 260/34 260/34 260/34 260/34
260/34
psig
70/21 260/35 260/35 260/35 260/35
260/35
psig
80/27 273/36 284/36 285/36 285/36
285/36
psig
90/32 285/37 288/37 290/37 290/37
290/37
psig
Note: The water control valve is factory set to maintain 260 ± 15 psi discharge pressure @ 70 F/21 C water.
1410 - Refrigerant pressure data
Air-cooled condensers (air)
60 F/16 C
70 F/21 C
80 F/27 C
90 F/32 C
100 F/38 C
Pressure (psig) discharge/suction
235/27
275/30
315/32
355/35
395/37
System Operating Pressures (Discharge/Suction) PSIG
Potable Water F/C