10
remote condensing
HARMONY • TOP-MOUNT
ICE CHUTE
GATE MOUNTING PLATE
GASKET
STORAGE HOPPER
ICE DIVERTER
10-32 WASHER
10-32 NUT
FLANGE EXTENDS INTO
STORAGE HOPPER
THROUGH GATE
OPENING
APPLY RTV TO THIS
SURFACE TO SEAL
TO HOPPER GATE
MOUNTING PLATE
ICE CHUTE
COVER
Cornelius ED, DF and DB series only
These dispensers require the installation of an ice diverter at the dispenser opening.
• Disassemble chute assembly
• Discard factory restrictor plate
• Replace with alternate diverter plate (supplied)
Dispenser diverter plate installation – CORNELIUS ED, DF and DB SERIES
3.12
Agitation adjustments –
Cornelius IDC and Flavor Fusion
3.13
These dispensers require modifications for compatibility with Chewblet ice. Agitation
times must be set to 1 second ON, 1 hour OFF and the ice restrictor plate must
be adjusted to the fully open position. See your beverage supplier for these
modifications.
Prior to installing the docking assembly, ensure
that the drain fitting is oriented (right or left)
correctly for your installation. An optional straight
drain fitting is also supplied. You may need to
remove the back panel of the docking assembly
in order to re-orient or change the drain fitting.
Replace back panel prior to mounting the
docking assembly.
BEFORE PROCEEDING