16
Horizon Elite 710/1010/1410
HARMONY • RIDE Technology
6.8
Water solenoid, shut-off valve, and
potable water line options
6.9
Cooling lines and power
6.9.1
If water solenoid is already mounted to
evaporator:
1. Insert potable water line into shut-off valve.
6.9.2
If this is an undercounter installation:
1. Mount water solenoid atop evaporator and
locate the shut-off valve
inside
the machine.
Insert potable water line into shut-off valve.
6.9.3
If water solenoid is not mounted and
machine will not be installed undercounter:
1. Mount water solenoid to inside rear (upper
right corner) of docking assembly using one
screw.
2. Insert potable water line into shut-off valve -
locate the shut-off valve
outside
the machine.
3. Insert outgoing line from shut-off valve into
push-in connection of water solenoid.
➊
➋
§
Connect cooling water lines to ice machine
➊
.
(Water "Out" connects to water regulator.)
§
Water valve is set at the factory.
DO NOT remove
seal or adjust water valve
➋
.
6.10
Power cord
6.11
Plate
§
Remove twist tie.
§
Carefully pass cord through opening and plug into
wall outlet.
§
For H_E units, install a suitable plug.
§
Position plate into opening and secure with
supplied screw.
WARNING!
Plate must be securely installed to ensure proper
equipment ground.