5
Cornelius • RIDE Technology
remote condensing
➋
➊
NEMA
5-15
➌
1/4" per foot
(6,4 mm per 0,3 m)
7/8"
∅
(22,4mm)
➎
3/8"
∅
(9,5mm)
➍
2 ft. x 1" OD
silicone tubing
and fittings
provided
Prepare the installation site.
2
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation of
low side is not recommended and will void warranty.
Electrical
➊
• 120/60/1-5 amps
Potable water supply
➋
(3/8” push-in internal connection, 3/8” OD tubing required)
• 10-70 psi (69-483kpa)
• 45-90 F (7-32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
• This equipment is to be installed with adequate backflow protection to comply with applicable
federal, state, and local codes
Drain
➌
(3/4” Barb)
• Minimum 8” radius on silicone drain line. Drain line from the ice machine must have at least
1/4" per foot pitch (6,4mm/0,3m).
Refrigeration lines
➍
• 7/8"
∅
(22,4 mm) diameter suction line (insulated)
➍
• 3/8"
∅
(9,5 mm) liquid line
➎
Installation site requirements
2.1