background image

13

DROP-IN • RIDE Technology 

remote condensing

Front cover

Install front cover to ice machine.

8

  •  Complete installation of condensing unit 

or connection to rack system.

Install condensing unit

8.1

  •  Slide ice machine cover over machine 

ensuring that tabs on back of cover 
slip under louvers on back of louvered 
docking assembly 

  •  Insert and tighten two screws through 

cover and into louvered docking assembly 

Install ice machine front cover

8.2

 

NOTICE

Ice machine MUST be sanitized prior to operation!

Consult Operation and Service Manual provided with ice machine for sanitizing instructions.

Summary of Contents for HCD000RJS

Page 1: ...MODE L AMPS AMPS PHAS E SINGL E CHAR GE LOW SIDE PART NO PSIG THE USA MADE IN OZ R C R HZ UL L NSF U HCD HMD HCF HMF1000RJS HCD HMD HCF HMF1400RJS HCD HMD HCF HMF1650RJS HCD HMD1000NJS HCD HMD1400NJS...

Page 2: ...aking head Self contained only D 115 60 1 icemaking head Self contained and remote If remote unit high side is 208 230 60 1 E 230 50 1 icemaking head Self contained only F 115 60 1 icemaking head Remo...

Page 3: ...mote condensing Front cover 8 Internal connection 7 Ice transport tube 5 External connection 6 Louvered docking assembly 4 Dispenser preparation 3 Site preparation 2 Unpack 1 Read and complete the fol...

Page 4: ...4 remote condensing DROP IN RIDE Technology Carefully unpack and inspect the contents of your Follett ice machine 1 Unpack 1 2 1 2 Unpack ice machine 1 1...

Page 5: ...eet 2m of ice machine in accordance with local and national codes Outdoor installation of low side is not recommended and will void warranty Electrical 120 60 1 6 amps Potable water supply 10 70 psi 6...

Page 6: ...h bulkhead fitting with flat up and tighten bulkhead nut Position and secure nut locking plate with supplied screws Verify installation of O ring on stainless steel ice transport tube coupling Insert...

Page 7: ...embly 4 1 25 4mm Stub Typ 3 76mm 1 3 4 44 5mm 3 76mm 3 8 high pressure line 1000 1400 5 8 low pressure line 1650 7 8 low pressure line Mount louvered docking assembly Rough in the refrigerant piping 2...

Page 8: ...of access panel door min of 1 75 45mm from the front edge of the cross brace The mounting surface for the louvered docking assembly must be solid Do not mount directly onto runners or channels There...

Page 9: ...tube Secure ice transport tube as needed to prevent dips and traps from forming For long tube runs see guide on page 14 Pitch ice transport tube at least 1 4 per foot 6 4mm 3m Ice transport tube must...

Page 10: ...onnections Remove access panel if necessary Install drain line The rigid drain line from the ice machine must have at least 1 4 per foot pitch 6 4mm 0 3m Install ice machine potable water supply Repla...

Page 11: ...3 Slide ice machine into louvered docking assembly Insert ice transport tube all the way into coupling and tighten nut firmly Ice transport tube installation 7 1 Insert potable water line into valve P...

Page 12: ...12 remote condensing DROP IN RIDE Technology Position plate into opening and secure with supplied screw Power cord 7 5...

Page 13: ...Slide ice machine cover over machine ensuring that tabs on back of cover slip under louvers on back of louvered docking assembly Insert and tighten two screws through cover and into louvered docking...

Page 14: ...IN RIDE Technology 1 4 1 max 2 ft 6m Pitch ice transport tube to allow melt water to drain towards ice machine Secure insulated ice transport tube at least every 2 ft 6m to prevent dips or traps Long...

Page 15: ...15 DROP IN RIDE Technology remote condensing...

Page 16: ...SA Toll free 877 612 5086 1 610 252 7301 www follettice com Horizon Maestro Harmony Ice Manager SafeCLEAN Sani Sponge RIDE and Vision are trademarks of Follett Corporation Chewblet is a registered tra...