Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that
you take a moment to review this manual before beginning the installation. Should you have any questions or
require technical help at any point, please call our technical service group at (877) 612-5086 or (610) 252-7301.
Before you Begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If
damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the filing of
a claim, if necessary.
Check your paperwork to determine which item number you have. Follett item numbers are designed to provide
information about the type of refrigerator you are receiving. Following is an explanation of the different item
numbers.
Model Number
Item Number
Keypad
Door
Stackable/Use with
Pedestal
Solid
Glass
REF4P
REF4P-00-00
X
X
REF4P-00-GD
X
X
REF4P-KP-00
X
X
X
REF4P-KP-GD
X
X
X
REF5P
REF5P-00-00
X
X
REF5P-00-GD
X
X
REF5P-KP-00
X
X
X
REF5P-KP-GD
X
X
X
Specifications
REF4P
31.38" (79.7 cm) H x 23.75" (60.3 cm) W x
27" (68.5 cm) D
Fits below 34" (86.4 cm) high ADA-
compatible counter
3.9 cu ft capacity
REF5P
34.00" height (86.4 cm) H x 23.75" (60.3 cm) W x
27" (68.5 cm) D
Fits below standard 36" (91.4 cm)
high counter
4.5 cu ft capacity
Electrical Specifications
115 V, 60 Hz, 1 phase
Full load: 4.1A
Minimum circuit ampacity: 15A
Maximum size of branch circuit overcurrent device: 15A
Refrigeration Specifications
Refrigerant
Charge Size (oz)
Maximum Design Pressures (psi)
High Side
Low Side
R134A
9
190
110
Installation Specifications
Ambient temperature must not exceed 100 F (38 C).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
CAUTION!
§
Equipment must be wired according to local and national electrical codes.
§
Always disconnect power before servicing refrigerator.
REF4P and REF5P Undercounter Refrigerators 3
REUC235