Side view
Front view
553mm
305mm
305mm
696mm
712mm
1264mm
794mm
305mm min
480mm min
153mm min
480mm min
432mm
661mm
water connection
hopper drain
beverage
pan drain
Automatic load units with 1 ice machine
Automatic load units with 2 ice machine
Specifi cations –––––––––––––––––––––––––––––––––––––––––––––––––––––
Electrical requirements
§
Each ice machine and dispenser requires separate circuit with electrical disconnect within 6m. Equipment
ground required.
§
230V, 50 Hz, 2A
Plumbing
Dispenser
§
3/4" PVC slip joint for hopper drain
§
3/4" PVC pipe nipple for beverage drain pan
§
3/8" ID red line tubing for water in
§
Drains should be hard piped and insulated. Maintain at least 6 mm per 304 mm (1/4" per 12 in.)run slope on
drain line run
Ice machine
§
Refer to Ice machine Installation Manual packed with ice machine for installation instructions
Clearance and access information
§
1296mm above counter
§
305mm on side opposite tower, below counter
§
Counter front or rear panel must be removable for service access to both sides of dispenser and ice
machine(s), if any
§
Below counter access to drain clean-out required on utility side of dispenser
§
See Ice machine Installation Manual packed with ice machine(s) for clearance requirements for automatic
load dispensers
EU155N Ice and Water Dispensers
5