Instruction manual HT95
Date : August 2007
Documentrev. : 3
Page : 4 / 15
1.4. Specifications
When crimping the Mini PV™ to wires, the following parameters must be met.
Wire Length Requirements:
•
Minimum ...................19.05 mm (0.75 in.)
•
Maximum ..................As Required
Insulation Diameters of Wires:
•
"A"Side(28-32AWG)..0.71-1.37mm
(0.028-0.054 in.) Dia.
•
"B"Side(22-26AWG)..0.91-1.52mm
(0.036-0.060 in.) Dia.
Strip length of Insulation:
•
Discrete and latch
Housing Applications.3.81-4.31 mm
(0.150-0.170 in.)
•
Rod Housing. ...........3.30-3.81 mm
Applications...............(0.130-0.150 in.)
Wire Barrel Crimp Height: (For All Applications)
•
Single Wire 22-26 AWG or
Two Wires 26-28 AWG 0.81-0.86 mm
(0.032-0.034 in.)
•
Single Wire 28-32 AWG or
Two Wires 30-32 AWG 0.66-0.71 mm
(0.026-0.028 in.)
Insulation Barrel Crimp Height:
•
Discrete Application . 2.84 mm (0.112 in.) Max.
•
Latch and Rod Housing
Applications...............1.75 mm (0.069 in.) Max.
Mini PV™ Receptacles:
•
loose Piece 22-32AWG
NOTE
Loose piece terminals have different part numbers than reeled terminals.
CAUTION
If the terminal and the tooling are not compatible, damage to the tooling could result. If
you wish to use a terminal with a part number other than the one that was ordered for
the HT95, check with your distributor or Föhrenbach Application Tooling NV to be sure
that the new terminal number is compatible with your hand tool.