2.6 EP-64 P Bodypack Transmitter
POWER
POWER to transmitter is on.
OFF
Power to transmitter is off.
OFF / POWER
(21)
This rotary pot (22) (unter the metal shield) matches the
sensitivity of the transmitter´s audio section to the level of
the connected microphone (lavalier- or head-worn mic) or line
source .
Recommendation see section 4.2 and 4.3
Gain / Empfindlichkeitsregler
(22)
Battery compartment to insert supplied size AA 1.5 V dry
batteries or a standard 1.2 V adapter, >2100 mAh size AA.
Refer to section 3.2
Battery Compartment
(23)
The label on the rear of the bodypack transmitter indicates the
available carrier frequencies and approval information.
Frequency Label
(24)
Shows adjusted channel as well as the current battery status.
The 64 channels are grouped into A to D with 16 channels 1 to
16 each.
Display
(25)
To secure the bodypack transmitter on your belt.
Belt Clasp
(29)
Permanently connected, flexible antenna.
Antenna
(31)
4-pin mini XLR connector with both mic and line level pins that
automatically match the connector pinout of the recommended
Fohhn microphone or optional instrument cable.
Audio Input
(30)
You can set 3 functions on the handheld
transmitter by pressing the SET button (16):
1. Changing channels
If you wish to change the channel, press the Set button (16)
once with a pointed object and hold two seconds until the
bank display A-D starts to flash.
Press buttons (17) and (18) to change to the required bank (A
to D). Press the Set button (16) again, channel indicator 1-16
should start to flash. Press buttons (17) and (18) change to
the required channel (1 to 16). Press the Set button (16) again
to activate the new channel.
2. Sound level adjustment / gain
If you wish to adjust the sound level setting, press the Set
button (16) until "x dB" flashes. You can adjust the preset
level for the microphone in 4 stages (-30dB / -20dB / -10dB
/ 0 dB) using the UP and DOWN buttons (17) + (18). Press
the SET button again to confirm the desired sound level.
Recommended: 0 dB
3. LOCK function
If you wish to "lock" the preset carrier frequency to prevent
malfunctions, press the Set button (16) until LOC flashes.
You can activate and deactivate the lock function by pressing
buttons (17) ON and (18) OFF. Press the Set button again to
confirm this action. The transmitter cannot be switched off in
LOC mode. Only Mute ON/OFF is enabled.
SET Key
(16)
(17)
(18)
You can set 2 functions on the handheld
transmitter by pressing the SET button (26):
1. Changing channels
If you wish to change the channel, press the Set button (26)
once with a pointed object and hold two seconds until the
bank display A-D starts to flash.
Press buttons (27) and (28) to change to the required bank (A
to D). Press the Set button (16) again, channel indicator 1-16
should start to flash. Press buttons (27) and (28) change to
the required channel (1 to 16). Press the Set button (26) again
to activate the new channel.
2. LOCK function
If you wish to "lock" the preset carrier frequency to prevent
malfunctions, press the Set button (26) until LOC flashes.
You can activate and deactivate the lock function by pressing
buttons (27) ON and (28) OFF. Press the Set button again to
confirm this action. The transmitter cannot be switched off in
LOC mode. Only Mute ON/OFF is enabled.
SET Key
(26)
(27)
(28)
(21) (30)
(25)
(31)
(26)
(27)
(28)
(23)
(29)
(22)
(24)
The EP-64 P bodypack transmitter operates with 64 reversible
frequencies in the 790 to 814 MHz UHF carrrier frequency range.
EP-64 P features a clear display, which shows the adjusted carrier
frequencies and battery status. Additionally, you can lock the set
carrier frequency and ON/OFF switch (21) against operating errors.
The antenna is flexible and permanently connected.
The solid metal body supports an optimal handling and covers the
controls.
EP-64 Set