The 2239 offers great flexibility of output styles –
manual control, program control, or “one-shot”
countdown timer control.

Output can be continuous or intermittent in any
operating style depending on the position of the

CYCLE

/

CONT

switch.

Manual Operation

For 

steady output

, put the 

CYCLE

/

CONT

switch in the

CONT

position (for continuous output) and press

MANUAL

button to 

on

For 

intermittent output

, set the length of the ‘on’ and

‘off’ cycles in the dip switches. Set 

CYCLE

/

CONT

switch to 

CYCLE

. Press the 

MANUAL

button to 

on

.

Programmed Operation

Fogging occurs during each program event.

Scheduled event: continuous output

Enter event days and times into the Day/Week
timer memory. 

Set 

CYCLE

/

CONT

switch to 

CONT

(continuous output).

Press 

MANUAL

button to 

auto

to begin program

operation. 

Scheduled event: intermittent output

Enter event days and times into the Day/Week
timer memory. Choose on and off cycle lengths and
enter settings in dip switches. 

Set 

CYCLE

/

CONT

switch to 

CYCLE

(repeating cycle

operation). Press 

MANUAL

button to 

auto

to initiate

program operation. 

Countdown Operation

To make the 2239 can act like a countdown timer,
program a single event of the desired length. 

Press 

RESET

to clear all events from timer memory,

then set the clock to the current day and time. Set
cycle times on the dip switches and the 

CYCLE

/

CONT

switch as desired. 

Enter a single event into memory (see above).
Specify the proper day for the event as well as the
start and stop times.

Press 

CLOCK

to return to operating mode. 

The event can begin immediately, or after a delay:

- For an immediate start, press 

MANUAL

to 

on

->

auto

. The unit will turn off at the programmed

end time.

- For a delayed start, press 

MANUAL

to 

off

->

auto

. The unit will start at the designated start

time and turn off at the end time. 

NOTE: When the single event has finished, turn off
the timer (

auto

-> 

off

), delete the programmed

event, or 

RESET

the clock. Otherwise the event will

repeat at its next programmed time.

SUMMARY OF OPERATION

SPECIFICATIONS

Voltage

Plug/Outlet

Model

50/60Hz, 1ø

Configuration

223910

110-120V

NEMA 5-15

223910J

100V

UC831A

223920

220-240V

NEMA 6-15

223920E

220-240V

Schuko

223920U

220-240V

UK

223920A

220-240V

Australia/China

Contact Rating 10A @ 240V (inductive load)
Cycle Time

1-100 minutes, adjustable