background image

7

Gain Compensated Split Outputs

The RedNet MP8R is able to provide two outputs from each mic channel: one direct and a second 
automatically gain-compensated to deliver a constant level. This arrangement allows one engineer 
(FOH, say) to control the analogue mic gain without affecting the signal level being received by a 
second engineer on the network. 

The output of the mic amp module feeds the A-D converter. Once in the digital domain, the signal 
is split into two streams. The first stream passes through unaffected to the corresponding Dante 
transmitter. The second stream passes through a DSP amplifier which automatically compensates 
for any changes made to the analogue audio level – either by the front panel controls or over the 
network. The unit will therefore appear as a 16-channel device on the Dante network, with channels 
1-8 being the direct outputs from the preamps and channels 9-16 the compensated outputs.

Gain compensation can be enabled individually for each mic channel.

Headroom Allowance
If during a performance an analogue mic level was reduced by 3dB, the DSP gain for the corresponding 
‘split’ channel would be increased by 3dB to maintain its overall signal level

. Note however, that this 

action would push the DSP section 3dB closer to its clipping point. To minimise the likelihood of the 
DSP ever reaching its clipping point an offset can be applied to allow for some reserve headroom.

The default headroom offset setting will be -6dB, but the user can select 0dB or -3dB from the tools 
menu under RedNet Control. The setting is applied to all channels 9–16.

The global range of the gain compensation available is currently limited to tracking ±12dB from the point at 

which it was enabled. 

Mic Inputs

1 – 8

Network

Interface

DSP

+48V

-20dB

Gain

2.4kΩ

Ø

Ch 1–8

Ch 9–16

Analogue Mic Amp

Remote Control

Gain Control

Audio

Network

A-D

Individual

Enables ch. 1–8

Global Offset

0/-3/-6dB

Gain  Compensation 

Block Diagram

Summary of Contents for RedNet MP8R

Page 1: ...User Guide www focusrite com FFFA001146 01 ON...

Page 2: ...cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13...

Page 3: ...d if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful inte...

Page 4: ...Power Requirements 12 REDNET MP8R OPERATION 13 First Use and Firmware Updates 13 Digital Clocking 13 Pull Up and Pull Down Operation 13 Front Panel Control Lockout 13 Gain Compensated Outputs 13 OTHER...

Page 5: ...e to read through the System User Guide so that they are fully aware of all the possibilities that RedNet and its software have to offer Should either User Guide not provide the information you need b...

Page 6: ...twork failure These ports may also be used to daisy chain additional units when operating in Switched mode Separate power input sockets on the rear panel allow one supply to be connected to an uninter...

Page 7: ...s from the preamps and channels 9 16 the compensated outputs Gain compensation can be enabled individually for each mic channel Headroom Allowance If during a performance an analogue mic level was red...

Page 8: ...id sync signal is received from the network or the RedNet MP8R is network master 4 RedNet Sample Rate Indicators Five orange indicators 44 1 kHz 48 kHz x2 multiple of 44 1 or 48 x4 multiple of 44 1 or...

Page 9: ...IP addresses secondary Unit MAC addresses primary Unit MAC addresses secondary Firmware Version for the unit Device name 48V Switches phantom power on for selected channel 2 4 k Selects low input imp...

Page 10: ...or the Dante network Use standard Cat 5e or Cat 6 network cable to connect to a local Ethernet switch to connect the RedNet MP8R to the RedNet network Adjacent to each network socket are LEDs which il...

Page 11: ...t installed the retaining clips will need to be attached to the power input sockets on the rear panel Insert each clip by squeezing together the legs as shown in the first image below aligning the pin...

Page 12: ...er Also ensure that when mounted in a rack the side vents are not obstructed Power Requirements RedNet MP8R is mains powered It incorporates Universal power supplies which can operate on any AC mains...

Page 13: ...r pull down percentage as selected in the Dante Controller application Front Panel Control Lockout To prevent accidental adjustment of any control that could affect a channel s audio level the MP8R fr...

Page 14: ...t Control image The signal level gain and input function settings are indicated for each channel PSUs A B Each illuminates if PSU has power input and all DC outputs are present Networks Each illuminat...

Page 15: ...The default is Off 16 channels are available allowing a maximum of 16 independent RedNet MP8R control paths Two devices should not be set to the same MIDI channel MIDI channel selection is saved with...

Page 16: ...RJ 45 receptacle Applies to Ethernet Dante XLR Connectors Connector type XLR 3 receptacle Applies to Audio Input Pin Cat 6 Core 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 Whit...

Page 17: ...B A Weighted typical Rs 150 Phantom Power 48V independently switchable per channel Pad 20dB independently switchable per channel High Pass Filter 6dB 65Hz 3Hz 12dB Octave independently switchable per...

Page 18: ...port will cause this LED to illuminate Secondary network Green LED Indicates that a network connection is present on secondary port when in redundant mode Not used in switched mode Sync Lock Green LE...

Page 19: ...opriate procedure for resolving the warranty issue In every case it will be necessary to provide a copy of the original invoice or store receipt to the distributor In the event that you are unable to...

Reviews: