17
Front Panel Indicators
Power [PSU A]
Green LED. Illuminates when an AC input is applied and all DC outputs are present
PSU B
[D64R only]
Green LED. Illuminates when an AC input is applied and all DC outputs are present
Network Connected
[Primary]
Green LED. Indicates that a network connection is present [on Primary port when in
Redundant mode. When in Switched mode, a valid network connection at either Primary
or Secondary network port will cause this LED to illuminate]
Network Secondary
[D64R only]
Green LED. Indicates that a network connection is present on secondary port when in
redundant mode. Not used in switched mode
Network Locked
Green LED. When unit is network slave, shows valid network lock. When unit is network
master, shows lock to indicated clock source. Flashing indicates external clock is
selected but not connected
Sample Rate
Orange LED for each: 44.1 kHz, 48 kHz, x2, x4
Pull Up/Down
Indicates unit is set to operate on a Dante pull up/down domain
RedNet Clock Source
Orange LED for each: Internal, MADI Input and Word Clock
MADI Input
Orange LED for each: Coaxial, Optical [and Auto]
MADI Clock Source
Orange LED for each: [SRC], RedNet, MADI Input and Word Clock
MADI Status
[RedNet 6]
Orange LED for each: SRC & O/P Varispeed
Signal
[D64R only]
2 Green LEDs: 1 input/1 output. Illuminate at -126 dBFS. Orange LED: Varispeed
Network Modes
[D64R Only]
Redundant
Allows unit to connect to two independent networks
Switched
Connects both ports to integrated network switch allowing daisy-chaining of device
Channel Count
MADI Clock
Rednet Clock:
Single
Double
Quad
Single
64
32
16
Single – Varispeed
56
32
16
Double
32
32
16
Double – Varispeed
28
28
16
Quad
16
16
16
Quad – Varispeed
14
14
14