![Focusrite Rednet A16R User Manual Download Page 5](http://html1.mh-extra.com/html/focusrite/rednet-a16r/rednet-a16r_user-manual_2314581005.webp)
5
InstALLAtIon GUIDe
Rednet A8R/A16R Connections and features
front Panels
1 . AC Power switch
2 . Power Indicators:
• PsU A – Illuminates when an AC input is applied and all DC outputs are present.
• PsU B – Illuminates when an AC input is applied and all DC outputs are present.
When both supplies are functioning and have AC inputs PSU A will be the default supply.
3 . Rednet network status Indicators:
• PRIMARY – Illuminates when the device is connected to an active Ethernet network. Also
illuminates to indicate network activity when operating in Switched mode on either port.
• seConDARY – Illuminates when the device is connected to an active Ethernet network.
Not used when operating in Switched mode.
• LoCKeD – Illuminates when a valid sync signal is received from the network, or when the
RedNet A8R/A16R unit is the Network Master. Flashes if external clock is selected but
not connected.
4 . Rednet sample Rate Indicators
Five orange indicators: 44 .1 kHz, 48 kHz, x2 (multiple of 44.1 or 48), x4 (multiple of 44.1 or 48)
and sample rate PULL UP/DoWn. These Indicators illuminate individually or in combination
to indicate the sample rate being used. For example, for a 96kHz Pull Up/Down setting, the
48kHz, x2 and Pull Up/Down indicators will illuminate.
5 . signal Level Indicators:
• InPUts – Tri-colour LEDs indicate audio signal levels at the inputs to the network:
Green: Signal present (illuminates at -42 dBFS)
Orange: -6 dBFS
Red:
0 dBFS
Continued...
RedNet A8R
RedNet A16R
1
2
3
4
5
6
7
1
2
3
4
5
6
7