background image

User Guide

www.focusrite.com

FA0769-02

Summary of Contents for REDNET 1

Page 1: ...User Guide www focusrite com FA0769 02 ...

Page 2: ...he cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged...

Page 3: ... uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense For Canada To the User This Class A digital apparatus complies...

Page 4: ... Front Panel 7 RedNet 1 Rear Panel 8 Physical Characteristics 9 Power Requirements 9 Other RedNet system components 10 Using RedNet Control 10 Appendix 11 Connector Pinouts 11 Performance Specifications 13 Focusrite RedNet Warranty and Service 14 Registering Your Product 14 Customer Support and Unit Servicing 14 Troubleshooting 14 TABLE OF CONTENTS ...

Page 5: ...tputs are electronically balanced on 25 pin Dsub connectors The unit can be configured with 0 dBFS equating to either 18 dBu or 24 dBu to conform to the EBU or SMPTE RP155 standards respectively The front panel contains a set of LEDs confirming network status sample rate reference level and per channel signal level About this User Guide This User Guide applies only to the RedNet 1 analogue interfa...

Page 6: ...le Product registration card with Bundle Code Registration gives access to RedNet Control RedNet drivers installed with RedNet Control Audinate Dante Controller installed with RedNet Control Dante Virtual Soundcard token and download instructions RedNet 1 User Guide this document PDF format RedNet System User Guide PDF format ...

Page 7: ... illuminates when the unit is connected to an active Ethernet network LOCKED illuminates when a valid sync is received via the network 4 SAMPLE RATE indication five yellow LEDs only one of these 44 1 kHz 48 kHz 88 2 kHz 96 kHz 192 kHz will be lit at a time to confirm the sample rate that the system is running at 5 LEVEL SETUP indication two yellow LEDs one of these will be illuminated to confirm t...

Page 8: ...ectronically balanced See page 11 for connector details 8 ETHERNET RJ45 network socket Use a standard computer network cable to connect this socket to a local Ethernet switch to connect the RedNet 1 to the RedNet network The socket has integral LEDs which illuminate to indicate connection to an active network port and network activity See page 12 for connector details 9 AC mains standard IEC recep...

Page 9: ...However if this is unavoidable the fan can be turned on and off from RedNet Control Ventilation is via slots in the enclosure at both sides Do not mount RedNet 1 immediately above any other equipment which generates significant heat for example a power amplifier Also ensure that when mounted in a rack the side vents are not obstructed Power requirements RedNet 1 is mains powered It incorporates a ...

Page 10: ...of RedNet 1 will appear on screen in RedNet Control when a unit is included in the active system Metering Each input and output has 3 virtual LEDs corresponding to the levels indicated by the tricolour LEDs on the physical front panel These illuminate at 42 dBFS 6 dBFS and 0 dBFS respectively Tools menu four options are offered Level Ref 24 dBu sets internal analogue reference level for 0 dBFS to ...

Page 11: ... OUTPUTS 1 8 Pin Signal Pin Signal 1 Ch 8 hot 14 Ch 8 cold 2 Ch 8 screen 15 Ch 7 hot 3 Ch 7 cold 16 Ch 7 screen 4 Ch 6 hot 17 Ch 6 cold 5 Ch 6 screen 18 Ch 5 hot 6 Ch 5 cold 19 Ch 5 screen 7 Ch 4 hot 20 Ch 4 cold 8 Ch 4 screen 21 Ch 3 hot 9 Ch 3 cold 22 Ch 3 screen 10 Ch 2 hot 23 Ch 2 cold 11 Ch 2 screen 24 Ch 1 hot 12 Ch 1 cold 25 Ch 1 screen 13 n c ...

Page 12: ...12 Ethernet connector Connector type RJ 45 receptacle Applies to ETHERNET 1 1 8 1 8 Pin Cat6 Core 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown ...

Page 13: ...e 20 Hz 20 kHz 0 15 dB THD N 0 001 unweighted 1 dBFS input 20 Hz 22 kHz Dynamic Range 119 dB A weighted 60 dBFS method Converter dynamic range 120 dB Signal to noise ratio 119 dB A weighted 20 Hz 20 kHz Crosstalk Input or Output to Input 90 dB all other channels at 0 dBFS Input or Output to Output 100 dB all other channels at 0 dBFS Digital Performance Supported sample rates 44 1 48 88 2 96 192 kH...

Page 14: ...en advise you of the appropriate procedure for resolving the warranty issue In every case it will be necessary to provide a copy of the original invoice or store receipt to the distributor In the event that you are unable to provide proof of purchase directly then you should contact the reseller from whom you purchased the product and attempt to obtain proof of purchase from them Please do note th...