 INFORMATION FOR INSTALLERS

The burner is designed to run on Natural or LPG gas. The burner unit is not 

interchangeable between gas types.

The fire is an open radiant log effect appliance which can be placed 

directly inside any fireplace opening of the dimensions stated within the 

installation instructions.

Ventilation : any air vent shall be fitted in accordance with national 

regulations.

IMPORTANT

These instructions have been compiled in accordance with EN 509.

Ensure that the appliance corresponds to the type of gas it is to be used 

with. This can be confirmed by checking the data badge located on the 

appliance.

It is required that any appliance using gas is installed by a competent 

person, in conjunction with the instructions and the requirements as laid 

down in the relevant Regulations.

The installation must be in accordance with the Gas Safety Installation and 

Use Regulations 1984 and with these instructions, and all the relevant parts 

of the Local and National Building Regulations, and the recommendations 

of the relevant Codes of Practice.

· 

The Gas safety (Installation and Use) Regulations

· 

The Building Regulations

· 

The Building Standards (Scotland) (Consolidation) Regulations.

Appliance to be installed in accordance to national regulations.

IMPORTANT

All surfaces except the control knob, and lower front door opening knob 

are considered to be working surfaces.

Protection for young children or the infirm is not given by this appliance, 

and as such a suitable fireguard should be used in these conditions.

IMPORTANT

 SITING THE APPLIANCE

DIAMETRE: 180-250 mm

Dimensions B, D, H and h Determined by the user and it is the Installer 

responsibility to make sure a smoke test is carried out to prevent 

spillage.

 WARNING

The gas connection requires semi rigid pipe (8mm with fitting adaptor to 

1/2"BSP), not more than 1 metre in length, is recommended.

The appliance can be installed in any adequate area suitable for solid fuel 

fires and Fires.

The appliance must be located at least 250mm from any combustible 

materials.

HEARTH

The appliance must stand on a fireproof hearth.

To comply with the Building Regulations issued by the Department 

of the Environment, the following points should be noted when choosing 

a hearth:

1. The hearth must be made of non-combustible material of thickness  

  50mm minimum.

2. The hearth must protrude at least 300mm in front of the Fire and 150mm  

  each side.

User instructions

Summary of Contents for MAGMAFOCUS

Page 1: ...MAGMAFOCUS ____ INSTALLATION SERVICING AND USER INSTRUCTIONS...

Page 2: ...ARRANGEMENT TEST FOR SPILLAGE INSTALLATION INSTRUCTIONS OPERATING THE FIRE OPERATING INSTRUCTIONS A GENERAL NOTES B SETTING THE ELECTRONIC CODE first time use only C SETTING FAHRENHEIT OR CELSIUS D SE...

Page 3: ...INTS FOR THE PURCHASER This appliance is intended for decorative purposes only The Fire is designed to run off either Natural or LPG gas It is important to note that once a type of gas has been specif...

Page 4: ...tions The Building Regulations The Building Standards Scotland Consolidation Regulations Appliance to be installed in accordance to national regulations IMPORTANT All surfaces except the control knob...

Page 5: ...pable of delivering the required volume of gas in accordance with the relevant Standards A gas soundness test must be carried out before operating the Fire PRESSURE TESTING The gas pressure to the bur...

Page 6: ...d forward of the previous 3 pebbles 14 to 16 Place 1 pebble in both of the front corners of the burner 17 to 18 The remaining 4 pebbles are nested on top of the 2nd and 3rd row of pebbles 19 to 22 Thi...

Page 7: ...1 F 0 C to 55 C New and old batteries and different brands of batteries should not be used together Mixing of various batteries can cause the batteries to overheat leak and or explode WARNING Software...

Page 8: ...buttons simultaneously Minutes flash 6 To select minutes press or button 7 To confirm press and buttons simultaneously or wait E CHILD PROOF ON To activate press and buttons simultaneously displayed a...

Page 9: ...button ignition operation by pressing and holding button for 10 sec immediately after installing batteries ON is displayed and 2 is flashing When change is complete 2 will change to 1 NOTICE If the p...

Page 10: ...om temperature is lower than the set temperature the flame height stays on high for a longer period of time If the room temperature is higher than the set temperature the flame height stays on low for...

Page 11: ...tinue to PROGRAM 2 and set on and off times or stop programming at this point and PROGRAM 2 remains deactivated NOTE PROGRAM 1 and 2 use the same on Thermostatic and off temperatures for and Daily Tim...

Page 12: ...ce needs to be turned OFF manually for instance if the remote control is lost or the batteries become totaly flat the control valve must be accessed and the switch flipped to OFF marked 0 The picture...

Page 13: ...fire is burning on maximum turn off all other gas appliances in the house and calculate the fuel being burned from the gas meter Make sure that the burner is burning correctly The flames should be fa...

Page 14: ...14 Note...

Page 15: ...15 Note...

Page 16: ...tion dition Distribution Atelier dominique imbert S A S au capital de 102 355 euros 34380 Viols le Fort France Tel 00 33 0 4 67 55 01 93 Fax 00 33 0 4 67 55 77 77 Web www focus creation com Email info...