7
B. CLEARANCES TO SIDE WALLS
1/2’’cement board
(Durarock)
13 mm panneau de ciment
(Durarock)
1’’ rockwool insilation
(Roxul) attached to
backside of cement board.
25 mm isolant laine de roche (Roxul)
positionné juste derrière le panneau de ciment.
2x6’’ metal studs supporting
wall mounting plate.
montants métal 2x150 mm
supportant la platine murale
combustible wall
mur combustible
2’’
50 mm
1/2’’
12 mm
26’
’
660 mm
36’
’
915 mm
combustible wall
mur combustible
4’
1220 mm
CAUTION
THE DISTANCE TO A COMBUSTIBLE WALL MUST BE MAINTAINED AT 26 INCHES. PROPERTY DAMAGE OR
DEATH CAN OCCUR IF THIS DISTANCE IS NOT MAINTAINED. DRYWALL PRODUCTS LINED WITH PAPER
SUCH AS SHEETROCK ARE COMBUSTIBLE. CLEARANCES AS INDICATED FURTHER APPLY.
Manufacturer specifications:
• Corner configuration: this configuration necessit that you build an additional wall in the corner of the room. When placed
close to a noncombustible wall leave a minimum of 4 inches (from hearth which has a 27-9/16” diameter) for proper
ventilation. To avoid premature aging of your painted walls, only use mineral paint. With other paints, 38” clearances apply.
• Fire clearance to glass (from hearth): 31-1/2”.
• Fire clearance to vinyl windows: refer to window technical specifications..
IMPORTANT
Clearances may only be reduced by means approved by the regulatory authority.