![Focon Showtechnic EXPOLITE Retron LED 575 User Manual Download Page 33](http://html1.mh-extra.com/html/focon-showtechnic/expolite-retron-led-575/expolite-retron-led-575_user-manual_2314156033.webp)
DMX-Channel assignment
This device has several DMX personalities. In each personality a different number of DMX channels
is used and the reaction of the device differs accordingly. There are six DMX personalities with 2,
7, 16, 51, 55 and 64 channels selectable.
Because of changes in the firmware of the fixture, functions can be added or changed. You can find the current version
„DMX-Channels“ as PDF-file on the website, ready to download.
Using DMX512 Control
E-33
1
0-255
Master
Flow Effect
0-41
no function
42-83
Effect 1
84-125
Effect 2
126-167
Effect 3
168-209
Effect 4
210-255
Effect 5
2Ch Mode
2
1
0-255
Master
2
0-255
Outer Dimmer (White colour)
Outer Strobe
0-10
No function
11-240
Strobe slow to fast
241-255
Random strobe
4
0-255
Inner Dimmer
Inner Strobe (Ch 1 + 4 need to be on)
0-10
No funtion
11-240
Strobe slow to fast
241-255
Random strobe
6
0-255
Center Dimmer
Center Strobe (Ch 1 + 6 need to be on)
0-10
No function
11-240
Strobe slow to fast
241-255
Random strobe
5
7
7Ch Mode
3