background image

INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MODELS COVERED BY THESE INSTRUCTIONS

L30 PIANO 

L30 CASCARA  

L30 VALERIA 

AVAILABLE IN NG AND LPG

Focal Point Fires plc.

Christchurch, Dorset BH23 2BT

Tel: 01202 499330     

Fax: 01202 499326

www.focalpointfires.co.uk

e : [email protected]

WALL MOUNTED HIGH EFFICIENCY GAS FIRE

Please  note  :  Except  where  otherwise  stated,  all  rights,

including  copyright  in  the  text,  images  and  layout  of  this

booklet is owned by Focal Point Fires plc.  You are not per-

mitted  to  copy  or  adapt  any  of  the  content  without  the

prior written permission of Focal Point Fires plc. 

1

Revision E - 04/15

'

2015 Focal Point Fires plc.

PIANO

The products covered by this booklet are protected under

patent GB2275331C.

CASCARA

VALERIA

GB IE

Questions or problems with your appliance?

Don’t take it back to the store

just give us a call on 

01202 588601

we’re here to help

lines open between 9am and 5pm, Monday to Friday

Summary of Contents for L30 CASCARA

Page 1: ...t where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not per mitted to copy or adapt any of the content witho...

Page 2: ...ce is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then co...

Page 3: ...will operate correctly when exposed to normal gentle draughts experienced within the home It is not recommended however that the appliance be installed in areas where it is likely to be directly expos...

Page 4: ...cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the ap...

Page 5: ...only on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conv...

Page 6: ...proximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH set...

Page 7: ...f the young pets the elderly and the infirm Advise the customer that the ventilation openings should not be blocked or obstructed in any way Isolate the fire from the gas supply Ensure that the fire i...

Page 8: ...dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 11 000 hours 10 years of normal use After this time the catalysts should be replaced If there are any depos...

Page 9: ...re is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughl...

Page 10: ...he catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed...

Page 11: ...xed in position or can be moveable and can be used with open fires including combination grates or closed fires including room heaters and stoves See figures 2 3 for fireguard examples The fireguards...

Page 12: ...is not the cause then the ODS safety system may be in operation Switch the appliance OFF call in your installer to check the appliance and ventilation Remedial work must be carried out as required DO...

Page 13: ...GAS SAFE registration No Model Fire serial No Name contact details of installer Supplied by 4 2015 Focal Point Fires plc GB IE Date installed 11 0 SERVICE HISTORY Date of service Serviced by name Cont...

Page 14: ...through an authorised stockist retailer Please note all consumable items such as any ceramics including coals pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not co...

Reviews: