FITTING THE BURNER TRAY

Important Note: Check the thermocouple nut connection into the rear of the valve is secure.

Temporarily fit the burner tray and ensure a suitable gas route can be
achieved. Place the burner tray into the firebox making sure that the rear
lugs locate properly on to the ledge in the firebox. Fit the two securing
screws through the tray legs to secure the assembly.

Connect the gas supply and tighten the gas connections. Fit the
data/control plate to the tray using the two screws provided. Ensure that
the control knob can be pushed fully in and does not touch the plate.

Fit the deflector baffle to the two locations on the front face of the fire-
tray. Screws are provided for this purpose. The  baffle should be level with
the lower edge of the tray. Place the firefront in front of the fire tem-
porarily to check the angle of the baffle. The casting should fit well and
the control devices beneath should not be visible to the eye. Realign the
baffle slightly if necessary to achieve the correct fit.

GAS CONNECTION

Purge the gas supply to remove any air, and connect the previously installed gas supply to the control tap and tighten all joints.

If using an across hearth connection ensure the decorative frame and firefront will clear the supply route. If the data/control plate is not
already fitted, attach with two screws, ensuring the control knob is free to
be depressed fully.

FUEL BED LAYOUT

Fit the tapered brick pad into the securing brackets in the upper area of
the firebox. Place the large brick panel against the rear of the firebox

Place the ceramic combustion matrix onto the burner and the ceramic side
cheeks onto the matrix.

Place the front row of six coals on to the matrix, with the two coals sec-
ond front each end turned on their sides. Ensure the coals are firmly
against the side cheeks as shown in the photograph. If necessary, pull the
coals forward slightly to ensure their rear edges do not overhang the flame
ports. Corners or rough edges MUST NOT be allowed to enter the flame
ports. If in any doubt pull the coals as far forward as possible.

Place the middle row of five coals onto the flats in the matrix. Ensure the
coals are not put into the holes in the matrix. Place the two end coals firmly
against the side cheeks and back to the steps on the matrix, turning them on
to their sides as shown.

Place the rear row of four coals, making sure that the flat sides are firmly
against the brick panel and side cheeks as shown.

Note: The coals must not be crammed together, or   inserted into the holes
in the matrix. A well laid out,  generously spaced coal layout will give the
best results.

7

8.5

9.0

8.6

©

2008 Focal Point Fires plc.

Summary of Contents for BLENHEIM STYLE

Page 1: ...ser for safekeeping Revision C 10 08 Country s of destination GB IE MULTIFLUE GAS FIRE RANGE BLENHEIM STYLE ELEGANCE LULWORTH Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01...

Page 2: ...ad all these instructions before commencing installation This appliance must be installed in accordance with the rules in force and only used in a suf ficiently ventilated space The appliance is desig...

Page 3: ...e installation and use of this appliance This appliance is free from any asbestos material Refractories and coal bed are constructed from ceramic fibre 1 Section 1 0 2 0 3 0 4 0 4 1 5 0 6 0 7 0 7 1 8...

Page 4: ...more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the gases into the air A...

Page 5: ...t at the back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path in...

Page 6: ...FABRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The fra...

Page 7: ...in the rubber to slip snugly around the outside of the supply pipe and sleeving Note DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an...

Page 8: ...pe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIXING Drill four holes using a 8mm masonry bit to a depth...

Page 9: ...d firefront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Fit the tapered b...

Page 10: ...t row of six pebbles on to the matrix Ensure the pebbles are firmly against the side cheeks as shown in the photograph If necessary pull the peb bles forward slightly to ensure their rear edges do not...

Page 11: ...nition sequence as previously described and after turning the control knob through the spark position the knob should be held in and the pilot lit with a taper SETTING PRESSURE To commission the appli...

Page 12: ...will emit a newness smell for a time after initial commissioning and that extra ventilation may be needed during this time Advise that the fire is fitted with a spillage safety device O D S If the fir...

Page 13: ...e cleaning easier Do not damage or try to remove the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting REMOVI...

Page 14: ...or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant sectio...

Page 15: ...OT light position ensur ing the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten sec onds Now release the k...

Page 16: ...lue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage...

Reviews: