FocalPoint BLENHEIM STYLE Installation And User Instructions Manual Download Page 1

INSTALLATION AND USER

INSTRUCTIONS

All instructions must be handed to user for safekeeping

Revision C - 10/08

Country(s) of destination - GB/IE

MULTIFLUE GAS FIRE

RANGE

BLENHEIM STYLE

ELEGANCE

LULWORTH

Focal Point Fires plc, Christchurch, Dorset BH23 2BT

Tel: 01202 499330     Fax: 01202 499326

www.focalpointfires.co.uk

e-mail: [email protected]

Summary of Contents for BLENHEIM STYLE

Page 1: ...ser for safekeeping Revision C 10 08 Country s of destination GB IE MULTIFLUE GAS FIRE RANGE BLENHEIM STYLE ELEGANCE LULWORTH Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01...

Page 2: ...ad all these instructions before commencing installation This appliance must be installed in accordance with the rules in force and only used in a suf ficiently ventilated space The appliance is desig...

Page 3: ...e installation and use of this appliance This appliance is free from any asbestos material Refractories and coal bed are constructed from ceramic fibre 1 Section 1 0 2 0 3 0 4 0 4 1 5 0 6 0 7 0 7 1 8...

Page 4: ...more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the gases into the air A...

Page 5: ...t at the back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path in...

Page 6: ...FABRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The fra...

Page 7: ...in the rubber to slip snugly around the outside of the supply pipe and sleeving Note DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an...

Page 8: ...pe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIXING Drill four holes using a 8mm masonry bit to a depth...

Page 9: ...d firefront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Fit the tapered b...

Page 10: ...t row of six pebbles on to the matrix Ensure the pebbles are firmly against the side cheeks as shown in the photograph If necessary pull the peb bles forward slightly to ensure their rear edges do not...

Page 11: ...nition sequence as previously described and after turning the control knob through the spark position the knob should be held in and the pilot lit with a taper SETTING PRESSURE To commission the appli...

Page 12: ...will emit a newness smell for a time after initial commissioning and that extra ventilation may be needed during this time Advise that the fire is fitted with a spillage safety device O D S If the fir...

Page 13: ...e cleaning easier Do not damage or try to remove the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting REMOVI...

Page 14: ...or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant sectio...

Page 15: ...OT light position ensur ing the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten sec onds Now release the k...

Page 16: ...lue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage...