background image

Block diagram

R1: 1.2 Ohms / 20 Watts, 5% ceramic
R2: 8.2 Ohms / 20 Watts, 5% ceramic
R3: 4.7 Ohms / 20 Watts, 5% ceramic
C1: 220µF / 100V, 10% non polar capacitor (black color)
C1_1: 100µF / 100V, 10% non polar capacitor (black color)
C2: 220µF / 100V,10% non polar capacitor (black color)
C2_1: 100µF / 100V,10% non polar capacitor (black color)
C3: 8.2µF / 250V, 5% polypropylene capacitor (black color)
C4: 1µF / 250V, 5% polypropylene capacitor (black color)
C5: 1µF / 250V, 5% polypropylene capacitor (black color)
L1: 4mH air core inductor wire Ø1.00mm
L2: 0.27mH air core inductor wire Ø0.60mm
L3: 1mH air core inductor wire Ø0.85mm
L4: 0.16mH air core inductor wire Ø0.60mm
S1: switch 2 positions

L1

L2

L3

L4

C4

C5

Switch

Input +

Input -

C1

C1_1

W+

R1

R2

R3

C2

C2_1

C3

W-

T+

T-

M+

M-

7

Cross Uniq User ’s Manual

notice cross uniq.indd   7

notice cross uniq.indd   7

4/10/06   14:11:26

4/10/06   14:11:26

All manuals and user guides at all-guides.com

Summary of Contents for UTOPIA BE-CROSS UNIQ

Page 1: ...must be flush mounted The minimum load for the midrange driver of the N 7 Utopia Be kit is 0 3 liter Package contents 2 Cross Uniq crossovers 4 screws 5 x 20mm 1 user s manual Installation The Cross U...

Page 2: ...utputs of the Cross Uniq taking care to respect the polarity Connect the wire coming from the tweeter on the T and T terminals of the Cross Uniq taking care to respect the polarity Note The N 7 Utopia...

Page 3: ...The following diagrams only refer to Cross Uniq devoted to Utopia Be N 5 and Utopia Be N 6 kits 3 Cross Uniq User s Manual 0dB 3dB 1 2 All manuals and user guides at all guides com...

Page 4: ...5 polypropylene capacitor black color L1 0 35mH air core inductor wire 1 25mm L2 0 20mH air core inductor wire 0 85mm S1 switch 2 positions L1 L2 C4 Switch Input Input C1 W R1 R2 R3 C2 C3 W T T The f...

Page 5: ...5 The following diagrams only refer to Cross Uniq 7 devoted to Utopia Be N 7 kit 0dB 3dB 3 Demo room wiring 0dB 3dB 4 Car wiring Cross Uniq User s Manual All manuals and user guides at all guides com...

Page 6: ...0K 10K 5K 2K 1K 40 30 20 10 0 180 108 36 36 108 180 dBV Deg Hz Electrical frequency response curve The following diagrams only refer to Cross Uniq 7 devoted to Utopia Be N 7 kit All manuals and user g...

Page 7: ...or black color C3 8 2 F 250V 5 polypropylene capacitor black color C4 1 F 250V 5 polypropylene capacitor black color C5 1 F 250V 5 polypropylene capacitor black color L1 4mH air core inductor wire 1 0...

Page 8: ...in your country Your distributor can provide all details concerning the conditions of guarantee Guarantee cover extends at least to that granted by the legal guarantee in force in the country where th...

Page 9: ...le m dium du kit N 7 doivent imp rativement tre mont s en affleurement montage encastr Le volume de charge du m dium du kit Utopia Be N 7 ne doit en aucun cas tre inf rieur 0 3 litre Contenu de l emba...

Page 10: ...les sorties T et T du Cross Uniq en prenant garde de respecter les polarit s Attention Le kit Utopia Be N 7 est dot d un m dium de 8 cm La polarit du c blage de celui ci sur le Cross Uniq est fonctio...

Page 11: ...tice Cross Uniq Les sch mas suivants se r f rent uniquement au Cross Uniq consacr aux kits Utopia Be N 5 et Utopia Be N 6 0 dB 3 dB 1 2 All manuals and user guides at all guides com a l l g u i d e s...

Page 12: ...0V 5 condensateur polypropyl ne noir L1 0 35 mH self air fil 1 25 mm L2 0 20 mH self air fil 0 85 mm S1 commutateur 2 positions L1 L2 C4 Switch Input Input C1 W R1 R2 R3 C2 C3 W T T 50 20 50 100 500 2...

Page 13: ...r f rent uniquement au Cross Uniq 7 consacr au kit Utopia Be N 7 0 dB 3 dB 3 C blage pour d monstration sur baffle plan 0 dB 3 dB 4 C blage dans un v hicule 13 Notice Cross Uniq All manuals and user g...

Page 14: ...0 20 10 0 180 108 36 36 108 180 dBV Deg Hz Courbe de r ponse en fr quence lectrique 14 Notice Cross Uniq Les sch mas suivants se r f rent uniquement au Cross Uniq 7 consacr au kit Utopia Be N 7 All ma...

Page 15: ...F 100 V 10 condensateur non p laris noir C3 8 2 F 250 V 5 condensateur polypropyl ne noir C4 1 F 250 V 5 condensateur polypropyl ne noir C5 1 F 250 V 5 condensateur polypropyl ne noir L1 4 mH self air...

Page 16: ...vous sera rendu ou remplac en franco de port Dans le cas contraire un devis de r paration vous sera propos La garantie ne couvre pas les dommages r sultant d une mauvaise utilisation ou d un brancheme...

Page 17: ...s pr c dents haut parleurs D tes en quelques mots pourquoi vous avez choisi Focal Vos annotations ventuelles Composition de votre installation marque mod le Cassette CD Syst me de navigation Syst me m...

Page 18: ...All manuals and user guides at all guides com...

Page 19: ...installation brand model Cassette CD Navigation Multimedia center DVD Amplifier CD change Other elements In case of purchase of new equipment what were your former speakers Explain in a few words why...

Page 20: ...08 rue de l Avenir 42353 La Talaudi re cedex France Tel 33 04 77 43 57 00 Fax 33 04 77 43 57 04 SCOS 060931 3 Focal is a registered trademark of Focal JMlab www focal fr com All manuals and user guide...