background image

11

K2 Power subwoofers incorporate the 
very  latest  components.  To  ensure 
such  complex  mechanical  elements 
work  in  harmony  with  the  rest  of 
your system, they must be allowed to 
function correctly in this environment. 
Such  changes  in  temperature  and 
humidity are regarded as very hostile. 
For  K2  Power  subwoofers  to  benefit, 
a  running-in  period  must  be  used  to 
ensure they are prepared for this. We 
recommend  that  once  the  system  is 
ready  for  listening  the  subwoofers 
should  be  run-in  at  medium  volume 
setting.  The  use  of  audio  material 
that  contains  good  low  frequencies 
is  ideal  to  gain  their  full  potential. 
We  recommend  this  running  period 
be  used  for  at  least  one  week.  After 
which  the  excellent  performance  of 
your  K2  Power  subwoofers  can  be 
fully appreciated.

Fitting

Each  subwoofer  kit  comes  complete 
with its fixing kit. This consists of self-
tapping  wood  screws,  metal  inserts 
and  threaded  bolts,  plus  a  reel  of 
foam gasket material.
Depending on whether the subwoofer 
is  to  be  installed  standard  recessed 
flush-fit  or  inverted,  requires  careful 
examination  before  any  cutting  is 
attempted  for  example  a  rear  panel 
installation 

(fig. A)

. The desired baffle 

location  or  custom  made  enclosure 
must  be  rigid  and  strong  enough  to 
hold  the  weight  of  the  driver.  We 
recommend  the  sealing  gasket  is 
attached to the driver, then the driver 
placed  into  position  and  attached 
securely in place.

Installation

Running-in period

Connecting-up (general)

Connections (33 KX and 40 KX)

Both  33  KX  and  40  KX  subwoofers, 
use  a  dual  voice  coil,  thus  each 
consist  of  two  input  connectors.  To 
achieve  high  power  integration  to 
your  system,  we  recommend  the 
two  connectors,  are  connected  in  a 
parallel  circuit  formation 

(fig.  C)

.  In 

this  situation,  an  impedance  load  of 
approximately 1 ohms will be present. 
For  connection  to  the  amplifier,  it  is 
important  to  ensure  such  low  load 
is  compatible.  It  is  also  possible  to 
connect  the  voice  coil  into  a  series 
type circuit, producing an impedance 
load of approximately 4 ohms 

(fig. D)

.

This is generally recommended if your 
amplifier is not compatible to low load 
impedances of less that 1 ohms. The 
33 KX and 40 KX can also benefit from 
"Bi-amping"  configurations 

(fig.  E)

.  It 

is important to ensure both amplifiers 
are  of  the  same  specification  and 
power  rating.  Also  a  traditional  2 
channel  stereo  amplifier  (high  power 
recommended)  can  also  be  used, 
allowing further installation flexibility. 

It is imperative the correct connection 
is always maintained to the subwoofer. 
The  correct  phase  is  important, 
especially  when  integrating  it  into 
a  broad-bandwidth  or  component 
speaker  system;  such  in  the  case  of 
a  2  or  3  way  set  up.  Not  doing  so 
will  drastically  reduce  the  overall 
performance.
Connection  to  the  subwoofer  use 
the  standardised  system  of,  RED  = 
po, and BLACK = negative -.
This  must  be  followed  and  inverted 
if  the driver is  installed  in the  reverse 
(inverted install).
For those subwoofers with twin (33 KX 
and  40  KX)  or  quadruple  connection 
(46  KX  4),  careful  understanding  of 
the various parallel and series circuits 
must  be  determined  first,  by  verifying 
compatibility  with  the  amplifier  load 
characteristics,  and  overall  system 
integration.

Connections (27 KX)

The  27  KX  subwoofer  uses  a  single 
4  ohms  voice  coil,  thus  consists  of  a 
single input terminal 

(fig. B)

. Verify the 

output stage and if your amplifier has 
a  bridging  function,  to  gain  further 
benefit, use it. Ensure it is compatible 
with a 4 ohms impedance load.

English

notice sub k2 power gb   3

7/01/04, 17:21:49

Summary of Contents for K2 Power 27 KX

Page 1: ...tructure Extremely rigid structure improved power handling low distortion characteristics Multi ferrite motor unit Focals renowned multi ferrite motor continues with increased x3 level stack 33 KX 40...

Page 2: ...C D E Simple connection 4 ohms Connecting in parallel 1 ohms Connecting in series 4 ohms Double connection 2x2 ohms 27 KX 33 KX 40 KX 33 KX 40 KX 33 KX 40 KX English notice sub k2 power gb 2 7 01 04 1...

Page 3: ...onnectors are connected in a parallel circuit formation fig C In this situation an impedance load of approximately 1 ohms will be present For connection to the amplifier it is important to ensure such...

Page 4: ...n 1 ohm Connecting in series 4 ohms G F 12 H I J K Connecting in parallel 0 25 ohm Double connection in serie 2x2 ohms Double connection in parallel 2x0 5 ohm 4 amplifiers connected 4x1 ohm English no...

Page 5: ...an be included for parallel or series circuits fig I J Quad amping can be included with 4x separate amplifiers offering identicalspecifications Theimpedance load will be approximately 1 ohms fig K Aga...

Page 6: ...u ft F 3 41Hz Fast and tight bass 60 liters 2 19 cu ft F 3 37Hz Punchy and dynamic bass 80 liters 2 82 cu ft F 3 36Hz Deep and articulate bass SPL dB 1W 1m Frequency Hz 46 KX 4 Vented enclosure 80 lit...

Page 7: ...r installations For example up to 3 litres can be saved due to the same displacement lost by the array of multiferrites and large front and back plate assemblies and chassis For the 46 KX 4 around 4 l...

Page 8: ...weight 2106g 4 66Ib 2916g 6 42lb 2916g 6 42Ib 8100g 17 86lb Gap height 8mm 0 3in 10mm 0 39in 10mm 0 39in 10mm 0 039in Net weight 7 2kg 15 87Ib 9 8kg 21 6Ib 10 7kg 23 58Ib 17kg 37 47Ib Fs 48Hz 39Hz 34...

Reviews: