CLEARANCES TTO C
COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the appliance, providing the forward
projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper) positioned
too close to the appliance may discolour or scorch.
VENTILATION
This aappliance rrequires ppurpose pprovided vventilation oof aat lleast 88.75cm
2
. The requirements of other appliances operating in the same space
or room, and the results of a spillage test must be taken into consideration when assessing ventilation requirements, this will have been car-
ried out by your CORGI registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.
FUEL BED LAYOUT
1. Place the ceramic burner pad onto the top of the burn-
er as shown, taking care to ensure it is centralised and
pushed fully against the back location ledge. Check that
all of the holes in the burner top plate are unobscured.
2. Place the matrix into position as shown. Slide it back
to the rearmost position and centralise.
2
3.0
4.0
5.0
Maximum ddepth oof sshelf
M
Minimum ddistance ffrom ffinished hhearth
surface tto uunderside oof sshelf
100mm (4in)
745mm (29 1/4 in)
150mm (6in)
845mm (33 1/4 in)
203mm (8in)
895mm (35 1/4 in)