Foamit SP1.5L User Manual Download Page 3

 Page 3 of 4   | 11162018

User Manual: 0.4 gallon (1.5 liter) Pump-Up Spray Unit | English

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

 Model Number: SP1.5L, SP1.5LBK and related units

Operation Instructions:

1.  Confirm air pressure is completely released from unit by 

activating the pressure relief valve (located on the side of 

the pump assembly (LC-PA-SP1.5L)).

2.  Securely hold the unit and unscrew the pump assembly 

(LC-PA-SP1.5L) from the tank (TANK1.5L).

3.  Follow all instructions from chemical manufacturer.  Fill 

tank 3/4 full with pre-mixed solution.

Note: Do not overfill tank with solution.

4.  Securely hold the tank (TANK1.5L) and screw the pump 

assembly (LC-PA-SP1.5L) on. 

5.  Pressurize the tank by pumping approximately 20 to 25 

times, or until it becomes difficult to pump. 

Note: Do not overfill tank with air. The pressure relief valve 

will leak if the air pressure is too high.  

6.  To start spraying, point the wand assembly at the area 

you wish to spray and press down on the On/Off control 

to discharge solution.  Release On/Off control to stop 

spraying. 

7.  Spray nozzle can be adjusted by rotating it. Rotate 

clockwise to narrow pattern. Rotate counterclockwise for 

wider pattern

After Use Instructions: 

1.  Release air pressure from unit after each use by activating 

the pressure relief valve (located on the side of the pump 

assembly (LC-PA-SP1.5L)).

2.  Empty all solution in tank and run fresh water through 

unit to rinse parts thoroughly. 

Maintenance Instructions: 

Warning: Always depressurize unit before performing 

maintenance

.

To keep your unit operating properly, periodically perform the 

following maintenance procedures:

•  Check the pump assembly for wear and leaks.
•  Check the suction tube and screen for debris and clean as 

needed.

•  Periodically lubricate the pump seal with a food safe 

lubricant.  To lubricate the pump seal, raise pump handle 

and apply 5 to 10 drops of food safe lubricant between 

pump and pump sleeve.  

Note: NEVER USE LUBRICANTS SUCH AS WD40.  