Maintenance Instructions
To keep your unit operating properly, periodically
perform the following maintenance procedures:
•
Check the pump assembly for wear and leaks.
•
Check the suction line for debris and clean as needed.
•
Periodically lubricate the pump seal with food safe
lubricant. To lubricate the pump seal, raise the handle
of the pump assembly and apply 5-10 drops of food
safe lubricant between the pump and pump sleeve.
•
If foam quality decreases, replace wadding:
1.
Release air pressure from unit after each use by
pulling the green pressure relief valve
(a)
until the
red part of the stem is visible.
2.
Unthread the wand retaining nut
(h)
from the black
plastic wand.
3.
Remove the old wadding
(i)
, and insert the new
wadding.
4.
Thread the wand retaining nut
(h)
onto the black
plastic wand.
Note:
before installing accessories, depressurize the
unit according to After Use Instructions.
Attachment Instructions
Drain tube attachment:
5
Remove the wand retaining nut
(h)
and oring
(k)
from
the lance and set aside to use with the drain tube.
6.
Remove the spray tip
(j)
, leaving the wadding
(i)
in
the lance
(l)
.
7.
Insert the press fit adapter
(m)
into the retaining
nut
(h)
, then place the oring
(k)
behind the press fit
adapter
(m)
.
8.
Thread the lance
(l)
into the wand retaining nut
(h)
,
securing the oring
(k)
and press fit adapter
(m)
place.
9.
Press the drain tube
(n)
into the press fit adapter
(m)
.
All PSG12 attachments:
10.
Remove the wand extension
(o)
from the trigger gun,
leaving wadding
(i)
and oring
(k)
in the gun.
11.
Install the attachment by threading it into the trigger
gun. An additional oring will be supplied in the parts
package of the attachment.
h
h
n
o
m
i
i
i
l
k
k
a
1
6
2
3
7
9
5
10
11
j