Model: APW20HT
V20190916 • Page 12
c .
Lift the sink off and set aside.
d .
Remove the control box assembly and set it aside.
e .
Use a fluid evacuator to remove the remaining solution.
f .
Wipe down the base and remove collected sediment.
g .
Refill with clean solution.
h .
Place the control box assembly on the base.
i .
Connect the hose from the sink to the control box assembly.
j .
Place the sink on the base.
k .
Reconnect the air supply.
6
Troubleshooting
Issue
Solution
Solution doesn’t flow through the
Flexible Rinse Line or Flow-Thru Brush
• Check the hoses between the Sink and Control Box Assembly are
connected. Reconnect if necessary.
• Check the hoses between the Sink and Control Box Assembly are not
pinched or damaged. Repair or replace if necessary.
• Check the pump is functioning. Repair or replace if necessary.
Solution doesn’t drain.
Check the Drain Grate and Filter Bag for sediment buildup or blockage.
Clean or replace if necessary.
Summary of Contents for APW20HT