background image

           PON Optical Power Meter                                                                                                               

-12- 

 

 

press“

”to delete, “

”to cancel. Press“

”to delete, display the "Delete ..." 

that is being deleted, delete the automatically disappear. 

       

 

 

Section 

 Operation

 

5.1Press“

” to power on the device into the PON    testing interface. 

press“

”to select whether to automatically shut down after ten minutes. 

 

Press“

”into menu 

Summary of Contents for F-501 FTTX New PON

Page 1: ...PON Optical Power Meter 1 Notice Trademarks All trademarks mentioned in this manual are registered property of our Explanation The content of this manual is subject to our explanation...

Page 2: ...r 2 Catalog SECTION I OVERVIEW 3 SECTION SPECIFICATIONS 4 SECTION STANDARD PACKAGES 5 SECTION PANEL AND FUNCTIONS 5 SECTION OPERATION 12 SECTION TROUBLESHOOTING 16 SECTION ATTENTIONS 16 SECTION WARRAN...

Page 3: ...libration wavelength 5 With the PC through the USB connection for data transfer 254 records in equipment or software stored on a flight view delete 6 Containing common optical Power Meter module inclu...

Page 4: ...ment 1490 downstream measurement 1550 downstream measurement Spectral passband nm 1260 1360 1470 1505 1535 1570 Measurement range dBm 40 10 40 10 40 20 Isolation 1310nm dB 40 40 Isolation 1490nm dB 40...

Page 5: ...r Working temperature 10 60 Storage temperature 25 70 Dimensions cm 16 5 8 0 3 5cm Section Standard Packages Section Panel and Functions 4 1 Operating Instructions 1 PON optical power meter 1 set 2 Us...

Page 6: ...n 4 2 1 Power on OLT VIDEO 1490 1 550 nm connector O N T 1 3 1 0 n m connector Auto power off B a t t e r y p o w e r d i s p l a y LCD USB data cable Auto power off Indicator light Menu Select functi...

Page 7: ...d 1490nm 1550nm downstream test The measurement value will appear when there is light passing through the optical channel otherwise LOW will appear Icon tips off automatically after ten minutes press...

Page 8: ...set Relative value measurement According to the test requirements choose to display different wavelengths and reference values relative power value absolute power value reference value press or to ch...

Page 9: ...roblems red testing equipment for an exception Press or 1db increase or decrease the threshold Press Skip to next edit or operation Unit switching units used dBm or xW Press choose or change option Pr...

Page 10: ...ime and minutes after setting minutes and then press save time setting and exit Use or modify the value In the setup process press exit and cancel the setup Historical data View and delete historical...

Page 11: ...is at 15 45 on June 2nd 2009 0001 0002 data 0001 is the current view of the data serial number 0002 is the instrument in the total number of historical data use or change the current view of the data...

Page 12: ...ess to delete display the Delete that is being deleted delete the automatically disappear Section Operation 5 1Press to power on the device into the PON testing interface press to select whether to au...

Page 13: ...for example select the threshold value of the name test 1 as the first threshold group press the change will take effect Press go back to test page 5 2 Access to measuring optical fiber Pure optical...

Page 14: ...i e 1310nm upstream 1490nm and 1550nm downstream at the same time For example threshold value of the name test 1 3dBm 20dBm 30dBm the measurement readings of the meter are the value for 1310nm upstrea...

Page 15: ...as shown above data record number is 2 Confirm the save by press cancel Test records can view stored in the Record View from historical data menu Record View 5 4 Data upload The measurement results ca...

Page 16: ...he performance of entire system may degrade Fault performance Possible causes Solution No LCD display Or can not boot 1 Power is not turned on 2 Power isn t enough 1 press open 2 Replace the batteries...

Page 17: ...e of shipment If any product defect within the above said period we will repair or replace the defective product however in no events we will bear responsibilities in excess of the product s sales pri...

Page 18: ...ce or incidence Warranty Registration The product is accompanied by a Warranty Registration Card please complete it and send it back to us together with a photocopy of the invoice they will be used as...

Page 19: ...Seal Please keep this together cut the second line and on this basis send Please cut along the dotted line and return the company Product Type Product Serial Number Buy Date User Name TEL FAX Address...

Reviews: