Serial port connection (RS485)

 

 
 
 

 

        * drilling  
          dimensions 

 
 
 
 
 
 
 
 
 

 

The second cable entry point is intended for the serial port connection. Remove the key touchpad 
and take the sealing element out of the cable entry point. Pass the cable through the cable entry 
point and attach it to clamps 1, 2, 3 and 4. Fix the cable to the cable duct entry. Ensure that the 
cable diameter meets the cable duct entry guidelines otherwise the IP protection rating is not 
achieved. Then screw the key touchpad back on again using the four screws. 

 
 
 
 

*

 

*

 

Summary of Contents for Indutel GSM

Page 1: ...Weatherproof GSM telephone FHF BA 9605 50 12 09 Operating manual...

Page 2: ...4 Serial port connection 5 Operating instructions 6 Control elements 6 Key touchpad 6 Making receiving calls 6 Dialing 6 Programming 6 Setting call volume 7 Setting call melody 7 Setting speaker micr...

Page 3: ...arge status is reported via SMS to the number pre programmed for this purpose 6 When receiving calls the Indutel GSM will ring at a volume and with the melody programmed by you 7 When programming the...

Page 4: ...onnector red cable to clamp 9 Solar panel or voltage supply connection Push the solar panel cable or DC voltage supply cable through a cable fitting and put the end of the cable onto clamp 5 and 6 Not...

Page 5: ...e the sealing element out of the cable entry point Pass the cable through the cable entry point and attach it to clamps 1 2 3 and 4 Fix the cable to the cable duct entry Ensure that the cable diameter...

Page 6: ...one call lift the receiver to answer the call To make a call lift the receiver and dial the number you would like to call Dialling Enter the number you would like to call using the touchpad The star k...

Page 7: ...is equal to 0000 Upon successful programming the Indutel GSM will send the following SMS FHFnnnnnn OK nnnnnn Telephone ID number alpha numeric If programming was unsuccessful the following SMS is ret...

Page 8: ...first SIM card SMS text FHF0000 FHF SIMCHK SIM2 NOR Programming emergency numbers SMS text FHF0000 FHF TNUM1 49 In an emergency the programmed phone number receives an SMS such as FHF000000 ALARM VBA...

Page 9: ...was replaced Receiving DLE If a NAK negative acknowledgement or any other signal is sent back as a DLE or there is a timeout sending is repeated 6 times Sending is terminated after 6 unsuccessful att...

Page 10: ...ion connected to a solar panel or DC voltage The recommended voltage range is to be adhered to Correct polarity connections are to be observed Connecting cables are to be positioned in such a way as t...

Page 11: ...t x width x depth Weight telephone incl telephone holder Operating position Receiver Speaker capsule Receiver capsule Connections Operating environment temp Transport and storage temperature With full...

Page 12: ...95 EG and the R TTE guideline 1999 5 EG Conformity to the guidelines listed above is verified by the C E Conformit Europ enne sign Electronic devices and old electrical items with this symbol may cont...