Web:
www.fmuser.net
Email:
Skype:
rita.cai87
MSN:
9
/
11
(
2
)
Temperature protection
In the protection setting page, press
【
▼
】
button to enter in temperature protection setting
page. Press
【
▲
】
or
【
▼
】
button to adjust the temperature between 50
℃
~70
℃
, then press
【
】
back to the protection setting page. Press
【
】
again to exit. The transmitter stays in working
status.
Temperature Protection Setting page
Remark: The default temperature protection value is 60
℃
, normally there is no need to change.
17. Reset to factory setting
Press and hold
【
▲
】
, then connect the power supply, release the button to enter reset setting.
No.
Item
EX-Factory Value
1
Frequency
98MHz
2
Power output
5W
3
LINE Volume
05
4
MIC Volume
15
5
MONO/STEREO
Stereo
(
ST
)
6
VSWR
2.5
7
Temperature
60
℃
8.Technical Specification
NO.
Item
Technical Specification
1
Working Voltage
DC12V~16V
(
Rated DC15V
)
2
Working Current
﹤
3A
3
Frequency Range
87~108MHz
4
Frequency Stability
±10PPM
5
Frequency Stepping
100KHz
6
Environment Temperature
-10
~45
℃
℃
7
Output Resistance
50Ω
8
RF Output Power range
0.2W~15W
9
Harmonics&Spurious
≤
-
60dB