FMUSER INTERNATIONAL GROUP INC Support: http:// fmusersupport.com
11
/
18
Temperature Protection Setting
On the Menu page, turn the knob to page 6 TEMP setting, press the knob to enter setting. Turn
the knob to adjust the protection temperature point within the range of 30~80
℃
, then press
the knob to confirm setting and exit.
SWR protection setting
On the Menu page, turn the knob to page 7 SWR SET setting, press the knob to enter setting.
Turn the knob to adjust the SWR protection point within the range of 1.0~5.0, then press the
knob to confirm setting and exit.
Line Mute setting
On the Menu page, turn the knob to page 8 MUTE setting, press the knob to enter setting. Turn
the knob to set Mute status, ON means the line-in is muted, OFF means the line-in is
available. Press the knob to confirm setting and exit.
Exit setting
On the Menu page, turn the knob to page 9 MENU EXIT, press the knob to exit setting and
return to main page.