Operating Instruction EMGZ491.EIP
17.03.2022
20
Limit frequency low-
pass filter actual value
The amplifier features a low-pass filter that filters the
measured value, which is relayed via ETHERNET/IP. This
filter is used for suppressing undesired interference
signals that are superimposed on the measuring signal.
Using this parameter, the limit frequency of the filter is
adjusted. The lower the limit frequency, the slower the
measuring value.
This low-pass filter is independent from the output filter.
Unit
Hz
Min.
0.1
Max.
200.0
Specified value
10.0
Low-pass filter analog
output active
Here, the status of the low-pass filter for the analog
output is indicated.
This parameter cannot be accessed via the web interface.
Min.
0
Max.
1
Specified value
1
0 = no, inactive, 1 = yes, active
Limit frequency low-
pass filter analog
output
The amplifier features a low-pass filter that filters the
signal of the analog voltage output. This filter is used for
suppressing undesired interference signals. Using this
parameter, the limit frequency of the filter is adjusted.
This low-pass filter is independent from the ETHERNET/IP
filter.
Unit
Hz
Min.
0.1
Max.
200.0
Specified value
10.0
Analog output scaling
This parameter determines, for which force the analog
output outputs its maximum voltage (10 V).
Note:
If lb (pound) is selected, the system switches from metric
to imperial measuring units.
Unit
N
Min.
0.1
Max.
200‘000.00
Specified value
1‘000.00