Operating Manual BMGZ710 and BMGZ710.PNET
20.04.2021
26
7.3
Manual batch weighing
Illustration 12: Manual weighing of a batch
-
Start the conveyor belt without any load
-
Press the “Reset” softkey on the home screen
-
The batch amount is set to zero
-
The batch counter is incremented
-
Run the desired amount over the conveyor system.
-
End loading and run the belt empty.
-
The display will now show the quantity that has just been conveyed under “Batch”
7.4
Manual batch weighing – with storage in the alibi protocol
Illustration 13: Manual batch weighing with storage in the alibi protocol
-
Start the conveyor belt without any load
-
Press the "Start" softkey on the “Batch” home screen
-
The batch amount is set to zero
-
The batch counter is incremented
-
Run the desired amount over the conveyor system.
-
End loading and run the belt empty
-
The display will now show the quantity that has just been conveyed under “Batch”
-
To end the batch, press the “Stop” softkey.
After the measurement is complete, the values (start time, end time, batch amount,
and batch number) are automatically and securely saved in the so-called alibi protocol.
You can retrieve data from the alibi protocol via the web browser or in the configuration
under the “Alibi protocol” menu item.