ALSO IN SELECTING A LOCATION, THE 

FOLLOWING PRECAUTIONS MUST BE 

OBSERVED: 

 

1.

 Do not connect this fireplace to a chimney system 

other than an 

FMI

 chimney system. 

 

2.

 Install in an area providing ventilation and 

adequate combustion air. 

 

3.

 Due to high temperatures do not locate this 

fireplace in high traffic areas or near furniture and 
draperies. 

 

4.

 Provide adequate clearances around air openings 

into the combustion chamber.  

NEVER

 obstruct the 

front opening of the fireplace or the flow of 
combustion and ventilation air. 

 

5.

 Do not locate in or near an area where gasoline or 

other flammable liquids may be stored. The fireplace 
area must be kept clear and free from these 
combustible materials. 

 

CLEARANCES 

 

MINIMUM CLEARANCES TO 

COMBUSTIBLES ARE: 

*

BACK....................................................  ...1/2” MIN. 

*ADJACENT WALL.......................................12” MIN. 
*CHIMNEY OUTER PIPE SURFACES....... ....2” MIN. 
*BOTTOM OF FIREPLACE TO FLOOR...... ...0” MIN. 

 

CAUTION:

 DO NOT BLOCK REQUIRED AIR 

SPACES WITH INSULATION OR ANY OTHER 
MATERIAL. DO NOT OBSTRUCT EFFECTIVE 
OPENING OF FIREPLACE WITH ANY TYPE OF 
FACING MATERIAL. COMBUSTIBLE MATERIAL 
MUST NOT BE IN CONTACT WITH THE BLACK 
FRONT FACE OF THE FIREPLACE. 

 

MANTLE CLEARANCES: 

 

  Woodwork, such as wood trims, mantles, and other 
combustible materials, should not be placed within 

9

 

inches of the 

effective opening

 of this fireplace. 

 

*The 

effective opening

 is considered the opening 

where actual heat output may occur 

  Combustible material above and projecting more 
than 

1-1/2

 inches from the fireplaces’ front face (see 

fig. 

4)

 should not be placed less than 

12

 inches from 

the 

 effective opening

 of the fireplace (ref; NFPA std. 

7-3.3.3.) 
 

 

FRAMING

 

Construct framing using dimensions shown in 
figures 

5, 7 

and 

depending on your particular 

installation.  
If the fireplace is to be installed directly on carpeting, 
tile (other than ceramic), or any combustible material 
other than wood flooring; the fireplace must be 
installed upon a metal or wood panel extending the 
full width and depth of the fireplace. 
Before securing fireplace to prepared framing, 

metal 

safety strips

 (provided) must be placed between 

hearth extensions 

(not supplied) and bottom front 

edge of fireplace to protect against glowing embers 
(figure 

6

). 

  If the fireplace is to be installed on a raised 
platform, a 

“Z-type” metal safety shield

 (not 

supplied) must be fabricated to fit your required 
platform height (see figure 

7

). The shield must be 

made of (26-28ga) galvanized sheet metal to prevent 
corrosion. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 4

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 3 

Summary of Contents for The Monterey PN36

Page 1: ...rom furniture and draperies Do not place clothing or other flammable materials on or near the appliance NEVER leave children unattended when a fire is burning in the fireplace WARNING IMPROPER INSTALL...

Page 2: ...INSTALLATION PG 5 8 CHIMNEY PIPE INSTALLATION PG 6 9 FINISHING YOUR CHIMNEY SYSTEM PG 8 10 TERMINATIONS PG 10 11 FINISHING YOUR FIREPLACE PG 11 12 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS PG...

Page 3: ...ough grounding may not be required by code in your area it must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70...

Page 4: ...TLE CLEARANCES Woodwork such as wood trims mantles and other combustible materials should not be placed within 9 inches of the effective opening of this fireplace The effective opening is considered t...

Page 5: ...mbustible floor surrounding fireplace You may obtain kit No HE P36 or you may fabricate your own per the dimensions shown on figure 10 The hearth extension must project 20 in min to the front and 12 i...

Page 6: ...stacles It should also be located beyond the reach of small children The maximum height for the air inlet above platform of fireplace is within 3 feet below the termination flue gas outlet For further...

Page 7: ...TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS ANZI IAS AGA Z21 11 2 ARE TO BE INSTALLED IN THIS FIREPLACE NOTE An appropriate FMI hood as shown in page 13 must be installed when using an unven...

Page 8: ...penetrating a floor or ceiling at an angle use firestop spacer no 30 FS 10DM refer to section on accessory items at the end of this manual When the pipe passes through a framed opening into a living...

Page 9: ...ee figure 21 FINISHING YOUR CHIMNEY SYSTEM IMPORTANT If an exposed portion of chimney is greater than 4 feet above the roof line use support wires to keep chimney secure The support wires may be attac...

Page 10: ...HIMNEY MAINTENANCE Have your chimney system cleaned and inspected regularly to ensure safe and efficient operation Refer to your Owners Manual for further guidelines on maintenance and operation Using...

Page 11: ...structions supplied with the termination The terminations approved for this fireplace are RTL 10D which can be used for flashing or chase and ETL 10D for chase style termination only Figure 27 shows a...

Page 12: ...refer to section on clearances and the fireplace opening are not blocked or obstructed in any way see fig 30 Use only heat resistant non combustible mortar or adhesive when securing facing material t...

Page 13: ...n starting a fire this pro vides adequate outside combustion air Close the mechanism when not in use to prevent cold air from entering the room Periodically check your outside air intake vent hood for...

Page 14: ...on the rating plate located inside the fireplace see figure 1 Refer to the parts list and diagrams when ordering replacement parts for your fireplace Repair parts or accessory items may be bought from...

Reviews: