background image

108796-01

Rev. U

09/09

WarraNty

keeP thIs WarraNty

FmI ProduCts, llC lImIted WarraNtIes

New Products

Standard Warranty:

 FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free 

from defects in material and workmanship for a period of four (4) year from the date of first purchase from 

an authorized dealer provided the product has been installed, maintained and operated in accordance with 

FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 

the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof 

to be free from defects in material and workmanship for 30 days from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with 

FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 

this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 

and only when installed by a qualified installer in accordance with all local codes and instructions furnished 

with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and 

an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider 

approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this 

product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use 

original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 

repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 

responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 

improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war

-

ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of 

any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to 

four (4) year on new products and 30 days on factory reconditioned products from the date of first purchase. 

FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC 

shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, 

or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 

incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 
For information about this warranty contact:

Model (located on product or identification tag)

 _____________________________

Serial No. (located on product or identification tag)

 __________________________

Date Purchased 

 __________________________

Keep receipt for warranty verification.

2701 S. Harbor Blvd.

Santa Ana, CA 92704

1-866-328-4537

www.fmiproducts.com

Summary of Contents for M36E, M36E

Page 1: ...GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instruction...

Page 2: ...nce may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indi cated on the...

Page 3: ...rating plate This appliance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate prop...

Page 4: ...pped on cardboard Three 3 plastic bags containing lava rock pan and ember materials Rear Log Remove two plastic quick ties from around burner and grate Grate Stand Lift off of burner pan Check all ite...

Page 5: ...ly piping system at test pressures equal to or less than 1 2 psig 3 5 kPa For the purpose of input adjustment two pressure taps for IN and OUT pressures are provided on the gas control valve for test...

Page 6: ...2 66 kPa 10 5 WC 2 66 kPa Orifice Size 30 29 GAS RATING PROPANE LP M36P B H VM36P B H M42P B H VM42P B H Max Input Rating 40 000 Btu Hr 45 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa M...

Page 7: ...ents in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section 1 1 2 3 8 cm Max 3 7 6 c...

Page 8: ...ack iron pipe does not mate with fitting at the end of flexible gas line remove fitting and replace with a 37 degree flare 3 4 12 1 2 NPT female fitting WARNING When finishing appliance do not overlap...

Page 9: ...st terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing roof jack or a roof thimble At all points the listed clearances must be maintained...

Page 10: ...r installation It is not recommended that this appliance be common vented with an existing gas burning appliance However if it becomes necessary to common vent this appliance the venting system must b...

Page 11: ...te Control Receiver Extension Cord Ignition Module Plug NOTICE This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of aventingproblem Donotbypas...

Page 12: ...TS LLC recommends that a black iron gas line be routed from the gas source through a sediment trap shown in Figure 18 and into appliance Once con nected through appliance a flexible gas line may be us...

Page 13: ...appear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Installation Continued Complete your gas installation by connect in...

Page 14: ...5 into notch on left of log 2 see Figure 25 Rest lower end of log 5 on grate as shown in Figure 26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper...

Page 15: ...5 Place upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log 1 see...

Page 16: ...Sealing Between Appliance and Framing Installing optional GLASS DOOR Accessory CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individuals If...

Page 17: ...is free of clip 2 Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail see Figure 35 CAUTION Always operate the appliance with the...

Page 18: ...toff Valve Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or los...

Page 19: ...sure to press ON OFF buttons on hand held remote control unit for up to 3 seconds to assure proper operation 2 Press the ON OFF button to turn burner on and off Check pilot flame pattern and burner f...

Page 20: ...and replace when cleaning is complete Burner and controls should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dir...

Page 21: ...ne Wiring Diagram Service Hints When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low if usi...

Page 22: ...ltage REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after repeated attempts applian...

Page 23: ...pane LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner...

Page 24: ...36EP B H M42E B H M42EP B H VM36E B H VM36EP B H VM42E B H and VM42EP B H 51 21 1 10 11 6 50 50 22 3 8 20 9 52 13 43 14 45 48 62 44 40 23 4 39 17 2 42 41 9 55 7 46 19 47 7 47 18 5 16 12 15 52 33 31 28...

Page 25: ...Deflector 1 25 11165 11165 Screw 10 x 5 8 2 26 107796 01 107796 02 Grate Assy 1 27 107742 01 107742 02 Burner Pan 1 28 107795 01 107831 01 Burner Tube 1 29 107748 01 107748 01 Burner Brckt 1 30 107985...

Page 26: ...M42EH 1 106660 01 107816 01 Rear Refractory Std Brick VM36EB VM42EB 1 108166 01 108171 01 Rear Refractory Herringbone VM36EH VM42EH 1 15 106661 02 107818 02 Bottom Rear Refractory Std Brick M36 ME42...

Page 27: ...and VM36P B H KEY NO PART NO DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 0...

Page 28: ...01 Left Front Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720...

Page 29: ...M42 B H and M42P B H BL36 36 Refractory Standard Brick BL42 42 Refractory Standard Brick BL36H 36 Refractory Herringbone Brick BL42H 42 Refractory Herringbone Brick For VM36 B H VM36P B H VM42 B H and...

Page 30: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Page 31: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___...

Page 32: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Reviews: