UNVENTED NATURAL GAS LOG HEATER

FIREPLACE MANUFACTURERS INCORPORATED

6

105191

AIR FOR
COMBUSTION AND
VENTILATION

Continued

Figure 3 - Ventilation Air from Outdoors

Figure 2 - Ventilation Air from Inside Building

Outlet
Air

Ventilated
Attic 

Outlet
Air

Inlet
Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Or

Remove

Door into

Adjoining

Room,
Option

3

Ventilation Grills 

Into Adjoining Room,

Option 2

Ventilation

Grills 

Into Adjoining 

Room,

Option 1

12"

12"

VENTILATION AIR

Ventilation Air From Inside
Building

This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see op-
tion 3, Figure 2). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation
 for
required size of ventilation grills or ducts.

 WARNING: Rework work-

sheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces.

IMPORTANT:

 Do not provide openings for

inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.

Summary of Contents for Heat Majic FVF18N

Page 1: ...e gas supplier s instructions If you cannot reach your gas sup plier call the fire department Installation and service must be performed by a qualified installer ser vice agency or the gas supplier WARNING Improper installation ad justment alteration service or mainte nancecancauseinjuryorpropertydam age Refer to this manual for correct installationandoperationalprocedures For assistance or additi...

Page 2: ...his heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace open ing has vents at the bottom you must open the vents before operating heater 7 You must operate this heater with a fire placescreeninplace Makesurefireplace screen is closed before running heater 8 This log heater is designed to be smoke less If l...

Page 3: ...ater has a piezo ignitor This system requires no matches batteries or other sources to light heater UNPACKING CAUTION Do not remove the metal Data Plates from the grate assembly TheDataPlatescontain important product information 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by the burner This could damage heater Always handle base assembly by grate 2 ...

Page 4: ...truction methods helpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion a...

Page 5: ...bustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 71 500 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space ...

Page 6: ...on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fr...

Page 7: ...reeheatersaddmois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Com bustion and Ventilation pages 4 through 6 NOTICE Stateorlocalcodesmay onlyallowoperationofthisappli ance in a vented configuration Check your state or local codes INSTALLATION AND CLEARANCES Vent Free Operation Only ...

Page 8: ...lace hood accessory HDABK or HDABR see Accessories page 21 18 Model Noncombustible material OK Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open NOTICE Manual control heaters maybeusedasaventedproduct If so you must always run heater with chimney flue damper open If running heate...

Page 9: ...required Followminimumclear ances shown in Figure 7 when using hood NOTICE If your installation does notmeettheminimumclearances shown you must do one of the following operate the logs only with the flue damper open raise the mantel to an accept able height remove the mantel Continued FLOOR CLEARANCES A If installing appliance on the floor level you must maintain the minimum dis tance of 14 to com...

Page 10: ...l burning fireplace with a working flue and constructed of non combustible material Ifyourheaterisamanuallycontrolledmodel you may use this heater as a vented product There are three reasons for operating your heater in the vented mode 1 The fireplace does not meet the clear ance to combustibles requirements for vent free operation 2 State or local codes do not permit vent free operation 3 You pre...

Page 11: ...PORTANT Hold gas regulator with wrench when connecting flexible gas hose 2 Locate two masonry screws in hard ware package 3 Place heater base in fireplace 4 Place logs in their proper position on heater base 5 Center heater base and logs front to back and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through one hole on each side of the mountin...

Page 12: ... certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas CAUTION Avoid damage to regulator Holdgasregulatorwith wrenchwhenconnectingittogas piping and or fittings Installsedimenttrapinsu...

Page 13: ...sures In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by ei ther using compressed air or opening main gas valve located on or near gas meter 4 Check all joints of gas su...

Page 14: ...ailuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury INSTALLING LOGS INSTALLATION Continued CAUTION After installation andperiodicallythereafter check to ensure that no flame comes in contact with any log With the heater set to High check to see if flames contact any log If so re...

Page 15: ...ow to vent smell Thiswillonlylastafewhours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the High heat setting but will find the heat output excessive You can open the chim ney damper if you have one fully or partially to release some of the heat WARNING...

Page 16: ... heater between PILOT and HIGH positions CAUTION Donottrytoadjust heating levels by using the manual shutoff valve The variable control valve can be set to anyheatsettingandflameheightdesired by simply turning the control knob until that setting is attained Even the lowest setting provides realistic dancing yellow flames Selectinghighersettingsproduces greater heat output This results in in crease...

Page 17: ...nect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace ignitor 7 Replace ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILO...

Page 18: ...atural gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burners see Cleaning and Mainte nance page 20 or replace burner orifice 1 Refer to Air for Combustion and Venti lation requirements pages 4 through 6 1 Properly locate logs see Installing Logs page 14 2 Eliminate source of drafts around heater 3 Clean out air holes at burner inlet Peri odically repeat as ne...

Page 19: ...h air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS oper...

Page 20: ...low the proper amount of air to mix with the gas This provides a clean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500 hours of operation or every three months Wealsorecommendthatyoukeeptheburner tube and pilot assembly clean and free of dustanddirt To...

Page 21: ... ready model number of your heater the replacement part number REPLACEMENT PARTS SPECIFICATIONS Heat Majic 18 Heat Majic 24 30 Variable Manually Variable Manually Controlled Controlled Btu Variable 16 000 27 000 16 000 31 500 Type Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Piezo Pressure Manifold 3 5 W C 3 5 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 Minimum 5 5 Shipping ...

Page 22: ...ED NATURAL GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED 22 105191 ILLUSTRATED PARTS BREAKDOWN HEAT MAJIC FVF18N FVF24N FVF30N ODS Pilot 4 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 2 18 13 19 17 20 18 3 1 ...

Page 23: ... 18 099056 18 Burner Orifice Injector 1 11 102843 01 102843 01 102843 01 Burner Clip 1 12 102963 01 102773 01 102773 01 Burner 1 13 102568 07 102568 07 102568 07 Control Valve 1 14 098508 01 098508 01 098508 01 Valve Retainer Nut 1 15 098354 01 098354 01 098354 01 Control Knob 1 16 102445 01 102445 01 102445 01 Piezo Ignitor 1 17 098249 01 098249 01 098249 01 Nut M5 2 18 099387 08 099387 08 099387...

Page 24: ... MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transpo...

Reviews: