AIR DEFLECTOR AND GLASS DOOR INSTALLATION

INSTALLING AIR DEFLECTORS (42'' 

MODELS ONLY)

Slide air deflector in between the front side 

face and side brick panel (see Figure 30, page 

17). The notched end of the deflector sits on 

bottom hearth. Air deflector does not require 

any fastening.

The  front  side  faces  and  side  brick  panels 

will  hold  the  deflector  in  place  (see  Figure 

30, page 17).

If you wish to install an unvented (vent-free) 

gas log set, only unvented gas log sets which 

have been found to comply with the standard 

for unvented room heaters, ANSI Z21.11.2 are 

to be installed in this fireplace.

  WARNING:  If  the  fireplace 

has been used for wood burning, 

the firebox and chimney must be 

cleaned  of  soot,  creosote  and 

ashes  be  a  qualified  chimney 

cleaner.  Creosote  will  ignite  if 

heavily heated.

  WARNING:  When  using  a 

decorative  vented  gas  log,  the 

damper  must  be  removed  or 

permanently locked in the fully 

open position and the glass doors 

must be in the fully open position.

OPTIONAL GAS LINE INSTALLATION 

Continued

PUREFIRE HOOD INSTALLATION

1.  The PureFire hood supplied with this fire

-

place is packaged in a separate box and 

placed in the firebox during shipping.

2.  Remove hood from box. Locate brackets  

(quantity  2)  and  screws  (quantity  4)  for 

hood installation in the hardware bag.

3.  Using screws provided, secure the bracket 

to the inner dome of the fireplace as shown 

in Figure 28. The left and right bracket are 

different. The edge that is straight will be 

closer to the fireplace opening. 

4.  Lift hood up into the fireplace and place it 

on the retaining brackets (Figure 28). The 

rear of the hood will touching the rear of 

the fireplace. 

Figure 28 - Installing PureFire Hood

DOOR FRAME MODELS 

BDMO42/50E/G/C

Installation

1.  Remove screws from smoke shelf (see 

Figure 29, page 30).

2.  Mount  top  door  frame  and  secure  with 

screws provided (see Figure 29, page 17).

3.  Place bottom door frame on top of ash lip 

at front of fireplace (see Figure 30, page 

17).

4.  Secure bottom door frame to brick with 

two  hex  screws  provided  as  shown  in 

Figure 30, page 17 using a 7/16" open 

end or adjustable wrench.

Summary of Contents for GMCAT42 Series

Page 1: ...to install and maintain your appliance it also contains information that will enable you to obtain re placement parts or accessory items when needed Keep it with your other important papers This fire...

Page 2: ...have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to hea...

Page 3: ...22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 Figure 1 42...

Page 4: ...0 MODELS 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3 4 Figure 2 50...

Page 5: ...by drafts air conditioning ducts windows or doors 3 A location that avoids cutting of joists or roof rafters will make installation easier 4 An outside air kit is available with this fireplace see Opt...

Page 6: ...arth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 5 WARNING Hearthextension is to be installed only as shown in Figure 4...

Page 7: ...ns Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inl...

Page 8: ...pipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward af...

Page 9: ...igure 13 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 2 cl...

Page 10: ...Secure in position by nailing through shingles see Figure 15 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation SC2 1 Place storm collar over pipe and slide down until it is snug against the...

Page 11: ...2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any ca...

Page 12: ...g Brackets 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the fireplace opening and into the slots on the side of...

Page 13: ...ng Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebri...

Page 14: ...UCTS LLC grate only see Parts page 22 This grate has been de signed to keep the operation of yourfireplacesafeandefficient FIREBRICK WALL INSTALLATION Continued Figure 25 Installing Grate Retainers IN...

Page 15: ...n apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATEANYAPPLIANCE IFALEAK IS D...

Page 16: ...lassdoors mustbeinthefullyopenposition OPTIONAL GAS LINE INSTALLATION Continued PUREFIRE HOOD INSTALLATION 1 The PureFire hood supplied with this fire place is packaged in a separate box and placed in...

Page 17: ...on on door adjustment Figure 31 Installing Bi Fold Doors Spring Clip Insert Pin into Spring Clip Pivot Hole Insert Bottom Pivot Pin into Hole Fold Door and Slide Top Pins Into Track Figure 32 Adjustin...

Page 18: ...als as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire we...

Page 19: ...d with petroleum products leaves paper products cardboard or salt driftwood Refer to your FMI PRODUCTS LLC Home owner s Guide included with your fireplace for proper fire building technique and ash re...

Page 20: ...those models that have not met this emissions level Exposure to smoke has been associated with respiratory illness and other health problems Models that have lower smoke emissions may reduce your risk...

Page 21: ...LACEMENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call FMI PRODUCTS LLC at 1 866 328 4537 to answer questions and replace parts under warr...

Page 22: ...www fmiproducts com 125701 01C 22 PARTS MODELS V GMCAT42 50 H S I R A SERIES AND V JMCAT42 50 H S I R A SERIES 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Page 23: ...Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 24 110146 03 Screen Rod 42...

Page 24: ...www fmiproducts com 125701 01C 24 PARTS MODELS V GMCAT42 50 H S I R A SERIES AND V JMCAT42 50 H S I R A SERIES Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9...

Page 25: ...25439 02 Right Stacked 50 Ivory 1 125427 02 Right Herringbone 42 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 125417 01 Left Stacked 42 Red 1 125441 01 Left Stacked 50 Red 1 125429 01 Left Herring...

Page 26: ...50E 50 Ebony BDMO50G 50 Pewter BDMO50C 50 Oiled Bronze DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND RETURN 30E 12DM and 30E 12HT O...

Page 27: ...ROOF FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM C...

Page 28: ...125701 01 Rev C 09 13 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com...

Reviews: