background image

12

901261

VENTED NATURAL GAS LOGS

LIGHTING

INSTRUCTIONS

OPERATING
APPLIANCE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some gas is
heavier than air and will settle on the
floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

GAS SHUTOFF

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the
gas shutoff valve counterclockwise

 to open or clockwise 

 to

close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise  
to the OFF position.

During the 2-3 hour appliance break-in
period, you may detect an odor from the
appliance as the various paints and com-
pounds used in the manufacturing of this
log set cure. This is a normal and tempo-
rary situation that is not cause for alarm.
However, you may want to provide extra
ventilation to the room during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1

hour.

• Burn the logs in consecutive 1 hour pe-

riods raising the flame an additional
2" to full flame height for a total of
three hours.

CURING LOGS

1.

STOP! Read the safety information,
above.

2.

Turn the gas shutoff valve to OFF.

3.

Wait five (5) minutes to clear out any
gas. If you then smell gas STOP! Fol-
low the safety information above. If
you don‘t smell gas, go on to the next
step.

4.

Light a match and lay it on top of
the pan material about 2" from the
end of the supply side of the pan

5.

Slowly turn the gas shutoff valve ON
until the burner ignites. If the burner
doesn’t ignite within 10 seconds with
the match burning, turn the shutoff
valve OFF and repeat steps 1 through
4 again.

Note:

 Operation instructions for GA9100

Remote Ready Valve/Pilot Kit will be
included with the kit.

1.

STOP! Read the safety information,
column one this page.

2.

Make sure equipment shutoff valve
is fully open.

3.

Press in and turn control knob clock-
wise 

  to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas around log set
and near floor. If you smell gas,
STOP! See Safety information
, page 2
and Air For Combustion And Ventila-
tion
, pages 4 through 6. If you don’t
smell gas, go to the next step.

5.

 Turn control knob counterclockwise

 to the PILOT position and

press in. Keep control knob pressed
in for five (5) seconds.

Note:

 You may be running this log

set for the first time after hooking up
to gas supply. If so, the control knob
may need to be pressed in for 30 sec-
onds. This will allow air to bleed from
the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the rear of the front burner. If
needed, keep pressing ignitor button
until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

 to the ON position. Burner

should light. If burner does not light,
call a qualified service person.

OPERATING

INSTRUCTIONS FOR

GA9000

Ignitor

Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

ON

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

OFF

On

Off

OFF

OFF

Pilot

Thermo-
couple

Figure 20 - Ignitor and Control Knob

Figure 21 - Thermocouple and Pilot

 WARNING: Keep flue open

when operating unit.

Summary of Contents for FMLR18

Page 1: ...onal procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuelburningmasonryo...

Page 2: ...nd fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set...

Page 3: ...s appliance See Acces sories page 19 A wall switch is also available for this appliance Youmustusethemillivoltvalve safety pilot kit to use the wall switch with this appliance See Accessories page 19...

Page 4: ...helpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible Whi...

Page 5: ...aws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can suppo...

Page 6: ...adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rewo...

Page 7: ...ATIONS Note This vented appliance must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical in...

Page 8: ...items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench C...

Page 9: ...all adapter fitting onto the burner inlet fitting using thread sealant on male threads of burner inlet fitting see Figure 9 Adjust to most conve nient position 4 Install the gas connector tube to the...

Page 10: ...ver ControlKnob and Piezo Ignitor Propane LP Gas Conversion To convert to propane LP gas the burner inlet fitting and pilot orifice must be re placed Thepropane LPburnerinletfittingis supplied with th...

Page 11: ...igure 17 Installing Grate Pan Material Not Shown Figure 18 Placement of Bottom Logs Changing Pilot Orifice The pilot is provided with a natural gas orifice installed For propane LP gas you must remove...

Page 12: ...If the burner doesn t ignite within 10 seconds with the match burning turn the shutoff valve OFF and repeat steps 1 through 4 again Note OperationinstructionsforGA9100 Remote Ready Valve Pilot Kit wi...

Page 13: ...ooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas Burner...

Page 14: ...nd tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reco...

Page 15: ...page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during...

Page 16: ...16 901261 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN FVMR18 FVMR24 3 1 8 6 12 10 11 10 4 2 7 9 5...

Page 17: ...3 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assembly 1 8 901232 01 901232 01 Gas Line 12 Aluminum 1 9 901...

Page 18: ...d under Replacement Parts on page 19 of this manual KEY PART NUMBER FOR NO FMLR18 FMLR24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619 01 90161...

Page 19: ...l models Carton of 6 GLOWING EMBERS GA9900 Not Shown For all models Use for firebox decoration only SILICA SAND GA9800 Not Shown For all models Use for firebox decoration only Carton of 6 LAVA ROCK GA...

Page 20: ...ted to repairing a defective log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Reviews: