www.fmiproducts.com
125009-01A
23
10. Wait one minute and switch selector
switch to the ON position to light burners.
Note: AUTO is only functional when using
GWMT1 or GWMS2 optional accessories.
11. Set flame adjustment knob to any level
between HI and LO.
12. You may shut off the burners and keep
the pilot lit by doing one of the following:
a. Turn control knob clockwise
to
the PILOT position.
b. Use remote control manual OFF button.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Figure 29 - Pilot (Propane/LP)
Ignitor
Electrode
Pilot
Burner
Figure 30 - Pilot (Natural)
Ignitor
Electrode
Pilot Burner
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the
OFF position.
2a. Set selector switch in the OFF position.
2b.
If Using Optional Hand-Held Remote:
Set selector switch in the OFF position to
prevent draining battery.
3. Close equipment shutoff valve (see Figure
17, page 17).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under
Lighting
Instructions
, page 22.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11,
Lighting Instructions
, page 22.
OPERATION
Continued
REMOTE-READy MODELS