background image

 

8

For more information, visit www.desatech.com

 
 
 
 
 
 
 
 
 
 
 
SUPPORT SECTIONS: (12S-8DM) 

 
The chimney support section is a 4-strap 12” length of pipe.  A 
chimney support is required at the 30-foot level above the 
fireplace after a straight chimney run (see figure 17). This 
support is designed to relieve the extra weight load on the 
fireplace and elbows when high chimneys are installed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PENETRATING THE ROOF: 

 
To maintain a 1-inch clearance to the pipe on the roof with a 
pitch, a rectangular opening must be cut. 
 
STEP 1: Determine the center point through which the pipe 
will penetrate the roof. 
 
STEP 2: Determine the pitch of the roof.  Pitch is the distance 
the roof drops over a given span, usually 12 inches.  A 6/12 
pitch means that the roof drops 6 inches for each 12 inches 
one measures horizontally down the roof. 
 
STEP 3: Use the roof-opening chart (see figure 19) to 
determine the correct opening length and flashing required. 
 
STEP 4: Remove the shingles around the opening measured 
and cut out this section. 
 
STEP 5: Add the next sections of the pipe until the end 
penetrates the roofline.  Check to see that the proper 
clearances are maintained. Extend chimney by adding sections 
of double wall pipe until pipe is a minimum of 30 inches 
above the highest point of the roof cutout.  Termination and 
chimney must extend a minimum of 36 inches above the 
highest point where it passes through roof. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 16          FIRESTOP INSTALLATION 

 IMPORTANT:

If an exposed portion of chimney is 

greater than four feet above the roofline, use support wires 
to keep the chimney secured.  The support wires may be 
attached to the outer pipe of the chimney with screws 
provided the screws do not penetrate the inner flue pipe. 

Figure 17         SUPPORT SECTIONS 

Figure 18         TYPICAL INSTALLATION 

 

 

 

Figure 19 

  ROOF FLASHINGS 

 

PITCH

SLOPE

OPENING "A" MAX

USE FLASHING

(degrees)

(inches)

MODEL NO.

FLAT

0

15

V6F-8DM

0 - 6/12

26.6

16 - 1/8

V6F-8DM

6/12 - 12/12

45.0

20 - 3/8

V12F-8DM

Summary of Contents for ELIMINATOR 36E

Page 1: ...DESA hood must be installed when using a vent free gas log set See accessories on pg 11 WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE DESA INTERNATIONAL...

Page 2: ...LLING THE FIREPLACE PG 3 8 HEARTH EXTENSION PG 4 9 OUTSIDE AIR KIT PG 4 10 GAS LINE INSTALLATION PG 4 11 VENT FREE GAS LOG INSTALLATION PG 5 12 COLD CLIMATE INSTALLATIONS PG 5 13 CHIMNEY PIPE PG 6 7 1...

Page 3: ...rtant step in ensuring safe and continuous operation of this fireplace SELECTING LOCATION To determine the safest and most efficient location for your fireplace consider the following guidelines The l...

Page 4: ...level of the fireplace and shim with sheet metal if necessary STEP 5 Before securing fireplace to prepared framing the ember protector provided must be placed between hearth extensions not supplied a...

Page 5: ...5 OPTIONAL OUTSIDE AIR KIT MODELS AK4E The outside air kit must be installed during the rough framing of the fireplace due to the nature of its location Outside combustion air can be accessed through...

Page 6: ...be installed when using an unvented gas log set see accessories on page 11 VENTED GAS LOG INSTALLATION If you install a decorative gas appliance vented gas log the decorative gas appliance must compl...

Page 7: ...wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained lineal gain after fitting overlaps must be taken into consideration see figure 12 Each double...

Page 8: ...as required by most codes When the double wall pipe passes through a framed opening into an attic space the firestop must be place into the attic floor as in figure 16 When the pipe passes through a...

Page 9: ...ermine the correct opening length and flashing required STEP 4 Remove the shingles around the opening measured and cut out this section STEP 5 Add the next sections of the pipe until the end penetrate...

Page 10: ...E TERMINATION BEING USED Terminations with 16 slip pipe sections are available The RTT 8DM and RTTL 8DM are approved for flashing or chase installations The ETL 8DM and ETLO 8DM are terminations that...

Page 11: ...inches above the opening of the fireplace see figure 25 Combustible materials above 9 inches and projecting more than 1 inches from the front face of the fireplace must be place at least 12 inches ab...

Page 12: ...visit www desatech com Desa International 2701 Industrial Drive P O Box 90024 Bowling Green KY 42102 9004 www desatech com 800 323 5190 CONTACT YOUR LOCAL DEALER ACCESSORY PARTS CONTACT YOUR LOCAL DE...

Reviews: