BURNER FLAME PATTERN

Figure 34 shows a correct burner flame
pattern. Figure 35 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows sporadic, irregular flame tip-
ping. It also shows the flame consistently
higher than one inch above the log.

Note:

  When using the fireplace the first

time, the flame will be orange for approxi-
mately one hour until the log cures.

If burner flame pattern is incorrect, as shown
in Figure 35

• turn fireplace off (see To Turn Off Gas to

Appliance, page 18)

• see Troubleshooting, pages 20 through 22

Figure 34 - Correct Burner Flame Pattern

Figure 35 - Incorrect Burner Flame Pattern

Top of Flame About
One Inch Above Log

INSPECTING
BURNER

Continued

CLEANING AND
MAINTENANCE

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

 WARNING: Turn off fireplace

and let cool before cleaning.

 CAUTION: You must keep con-

trol areas, burner, and circulating
air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fied service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes
clear of dust, dirt, lint, and pet hair. Clean
these air inlet holes prior to each heating
season. Blocked air holes will create soot. We
recommend that you clean the unit every three
months during operation and have heater in-
spected yearly by a qualified service person.

We also recommend that you keep the burner
tube and pilot assembly clean and free of
dust and dirt. To clean these parts we recom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can,  you could damage the pilot
assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 36).

3.

Blow air through the ports/slots and
holes in the burner.

Figure 36 - Injector Holder On Outlet
Burner Tube

4.

Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.

5.

Blow air into the primary air holes on
the injector holder.

6.

In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.

Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the pilot
assembly. There is a small pilot air inlet hole
about two inches from where the pilot flame
comes out of the pilot assembly (see Figure 37).
With the unit off, lightly blow air through the
air inlet hole. You may blow through a drinking
straw if compressed air is not available.

Burner
Tube

Injector Holder

Primary Air Inlet
Holes

Figure 37 - Pilot Inlet Air Hole

Ports/Slots

Pilot Assembly

Pilot Air
Inlet Hole

Summary of Contents for COMPACT HEAT MAJIC FMH26TP

Page 1: ...stallation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installation and operational pro cedures For assistance or addi tional information consult a qualified installer service agency or the gas supplier WARN...

Page 2: ...free from combustible materials gasoline andotherflammableva pors and liquids You must operate this fireplace with a fireplace screen in place Make sure fireplace screen is in place before running fireplace if you cannot reach your gas supplier call the fire department 4 This fireplace shall not be installed in a bedroom or bathroom 5 Do not use this fireplace as a wood burning fireplace Use only ...

Page 3: ...ower gas bills Ignitor Button Screen Fireplace Cabinet Logs Control Knob UNPACKING 1 Remove log box and fireplace from carton The hood is not attached IMPORTANT The fireplace hood is inside the cardboard protective end wrap on the left side of fireplace as viewed from front A decal is on the outside of the cardboard end wrap stat ing hood is enclosed see Figure 2 2 Remove hood from cardboard prote...

Page 4: ...ace log set on burner support see Figure 3 The log should fit flat against top of burner support and log locator tabs fit into the slots under the log Do not allow log to contact flame If flame contacts log soot will be created 5 Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down Figure 3 Assembling Fireplace Log Screen Burner Support with Log Loca...

Page 5: ...re have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames be tween sole plates and floors be tween wall ceiling joints between wall panels at penetrations for...

Page 6: ...gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support _____________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 56 000 Btu Hr actual amount of Btu Hr used The space in the above ...

Page 7: ...ombustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grillsorducts Youmustprovidetwoperma nent openings one within 12 of the ceiling andonewithin12 ofthefloor Connectthese items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel...

Page 8: ...ireplace insert in high traffic areas in windy or drafty areas CAUTION This fireplace cre ateswarmaircurrents Thesecur rents move heat to wall surfaces next to fireplace Installing fire place next to vinyl or cloth wall coverings or operating fireplace where impurities such as but not limited to tobacco smoke aromatic candles cleaning flu ids oilorkerosenelamps etc in the air exist may discolor wa...

Page 9: ...ify or cover the louvered slots on the front of the firebox Continued For convenience and efficiency install fireplace where there is easy access for operation inspection and service in coldest part of room An optional blower kit is available from your dealer see Accessories page 26 If planningtouseblower locatefireplacenear an electrical outlet 267 8 267 8 3 4 Off The Floor Minimum 10 1 2 Figure ...

Page 10: ...od base next to wall at instal lation location 10 Attach wood base to floor with two 1 3 4 black screws provided see Figure 14 Ifthefloorisconcreteuseanchormethod seeAttachingWoodBasetoSolidFloor page 14 11 Install gas line See Connecting To Gas Supply page 14 12 Check for leaks See Checking Gas Connections page 16 13 Place mantel around fireplace Be care ful not to damage wall or mantel 14 Place ...

Page 11: ...w Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swinging the assembly down see Fig ure 17 2 Using short Phillips screwdriver re move the screw under the center of the branch support Rotate valve cover shield clockwise and slide out IMPORTANT Do not remove shoul der screw on the left side of valve cover shield Slide the valve cover shield off of the ...

Page 12: ...here the valve shield was removed see Figure 18 7 Insert the 4 wire harness into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 18 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect green and white wires 9 Install the switch plate on the valve cover shield with 2 10 screws pr...

Page 13: ...from middle switch terminal 2 3 Remove black plastic strain relief and power cord from switch plate The power cord supplied will not be used in built in installations Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord strain relief 4 A licensed electrician must follow the wiring diagram to connect incoming electrical supply to fan kit wiring har ness see Figure...

Page 14: ...e Tap anchor flush to floor 4 Insert mounting screws through base and into floor anchors 5 Tighten screws until base is firmly fas tened to floor Figure 22 Folding Anchor Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 24 IMPORTANT Install equipment shutoff valve...

Page 15: ...ing Branch Support From Fireplace Figure 26 Attaching Flexible Gas Line to Equipment Shutoff Valve Branch Support Shoulder Screw Flexible Gas Line Screen CAUTION Usepipejointseal ant that is resistant to liquid pe troleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 24 page 14 Locate sediment trap where it is within reach for cleaning Install in piping sys...

Page 16: ... rect all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a noncorrosiveleakdetectionfluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external regulator has been installed be tweenpropane LPsupplyandfire place See guidelines under Con necting to Gas Supply page 14 Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shu...

Page 17: ...de lightpilotwith match To light pilot with match see Manual Lighting Procedure page 18 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 This fireplace has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise C clockwise to desired heating ...

Page 18: ... temperature depending on housingconstruction installationlocation room size open air temperatures etc Frequent use of your fireplace will let you determine your own comfort levels Shutting Off Fireplace 1 Turn control knob clockwise Clockwise to the OFF position 2 Turn off all electric power to the ap pliance if service is to be performed Shutting Off Burner Only pilot stays lit Turn control knob...

Page 19: ...heating season Blockedairholeswillcreatesoot We recommendthatyoucleantheuniteverythree months during operation and have heater in spected yearly by a qualified service person Wealsorecommendthatyoukeeptheburner tube and pilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may ...

Page 20: ...ed 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace piezo ignitor 6 Replace piezo ignitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down con...

Page 21: ...lace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit Whitepowderresidueformingwith...

Page 22: ...ment at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Fireplace produces unwanted odors Fireplace shuts off in use ODS operates Gas odor even when control knob is in OFF pos...

Page 23: ...art s call DESA International s Technical Service Department at 1 866 672 6040 for referral information WhencallingDESAInternational haveready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning typeofgasused propane LPornaturalgas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of ...

Page 24: ...PANE LP VENT FREE FIREPLACE SYSTEM ILLUSTRATED PARTS BREAKDOWN FMH26TP 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 19 6 22 31 21 41 26 42 39 39 16 15 18 24 12 28 5 34 25 27 20 4 35 24 14 25 14 40 3 37 17 12 ...

Page 25: ...02875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilot Tube 1 25 098271 06 Ignitor Cable 1 26 107186 01 Injector 1 27 101006 02 Pilot Bracket 1 28 098249 01 Nut M5 2 29 098522 22 Gas Valve 1 30 102639 01 Baffle 1 31 101628 01 Flexible Connector 1 32 102869 01 Control Bracket 1 33 102731 01 Control Shield 1 34 103295 03 Screen Assembly 1 35 107153 01 Log Set Assembly K...

Page 26: ...itisraisedoffof the floor Provides a finished appearance by covering rough edges of wall opening CLEANING KIT GCK Not Shown For all models Your vent free gas appli ance requires regular cleaning and mainte nance to prevent performance problems This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance CABINET MANTEL WITH FULL HEARTH BASE AND ROUNDED...

Page 27: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Page 28: ...ed by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUD...

Reviews: