Figure 47- Installing New Parts for Gas
Control Valve Conversion
HI
LO
O
FF P
IL
OT
O
N
Mounting
Screws
Rubber
Gasket
Identification
Label
2. Insure that rubber gasket is properly
positioned on new pressure regulator
assembly. Install new pressure regulator
assembly to valve using new mounting
screws supplied with kit. Tighten screws
securely (approximately 25 in/lb). See
Figure 47.
3. Install identification label enclosed with
gas valve regulator to valve body where
it can easily be seen (see Figure 47).
WARNING: The conversion
kit must be installed by a quali
-
fied service technician in accor
-
dance with the manufacturers
instructions and all applicable
codes and requirements of the
authority having jurisdiction. If
any information is these instruc-
tions is not followed correctly,
a fire, explosion or production
of carbon monoxide may result
causing property damage, per
-
sonal injury or loss of life. The
qualified service technician is
responsible for the proper in
-
stallation of this conversion kit.
GAS CONVERSION
Continued
SPECIFICATIONS
CD32M-LS AND CD32MB-LS
Natural Gas
• Rating: 12,000/18,000 Btu/Hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Orifice Size (Main Burner): #47 DMS
• Minimum Inlet Supply Pressure: 4.5" W.C.
• Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurements):
32
1
/
4
" x 34
1
/
2
" x 16
5
/
8
"
CD32M-LS AND CD32MB-LS
Propane/LP Gas
• Rating: 11,000/17,000 Btu/Hr
• Gas Type: Propane/LP Gas Only
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Orifice Size (Main Burner): #55 DMS
• Minimum Inlet Supply Pressure: 11" W.C.
• Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurements):
32
1
/
4
" x 34
1
/
2
" x 16
5
/
8
"
f i r e - p a r t s . c o m