VENTING INSTALLATION
Continued
Nail Only
Outer
Perimeter
of Flashing
Storm
Collar
Flashing
Cone
Underlap
Shingles
at Bottom
Overlap
Shingles Top
and Sides Only
Figure 19 - Flashing Installation
STORM COLLAR INSTALLATION
Place storm collar over pipe and slide down
until it is snug against the open edge of the
flashing (see Figure 20). Apply waterproof
caulking to all seams and notches around
storm and also at base around shingles.
Figure 20 - Storm Collar
Chimney
Pipe
Waterproof
Caulk
Storm
Collar
Flashing
TERMINATIONS
Standard Installation
The fireplace system must be terminated with
the listed round top or chase terminations.
Terminations approved for this fireplace are
RTL-8DM, which can be used for flashing or
chase and ETL-8DM for chase style termina-
tion only. Figure 21 shows an RTL-8DM round
top termination.
Follow installation instructions provided with
termination being used.
CAUTION: Do not seal open-
ings on the rooftop flashing. Fol-
low the installation instructions
provided with the termination
being used.
RTL-8DM
Collar
Flashing
Underlap
Shingles
Figure 21 - Terminations
Overlap
Shingles (Top
and Sides)
Caulk
Attach Bracket
Tabs to Outer
Pipe (3 places)
Secure with
Screws
5. Add next sections of pipe until end
penetrates roof line. Check to see that
proper clearances are maintained. Extend
chimney by adding sections of double wall
pipe until pipe is minimum of 30" above
highest point of roof cutout. Termination
and chimney must extend a minimum of
36" above highest point where it passes
through the roof.
IMPORTANT: If an exposed
portion of chimney is greater
than 4' above roofline, use
support wires to keep chimney
secured. Support wires may
be attached to outer pipe of
chimney with screws provided
screws do not penetrate inner
flue pipe.
FLASHING INSTALLATION
Determine flashing to be used with roof open-
ing chart. Slide flashing over pipe until base
is flat against roof. Replace as many shingles
as needed to cover exposed area and flashing
base. Secure in position by nailing through
shingles (see Figure 19).
DO NOT NAIL
THROUGH FLASHING CONE.